Evaporative Light Scattering Detector


Enhanced Sensitivity for Trace Analysis

The ELSD-LTII utilizes a high-efficiency LED and enhanced digital signal/
treatment to minimize noise and deliver optimum sensitivity for trace analysis.
An innovative cell design also reduces band broadening and allows sensitivity
levels below 200 picograms. The high-performance optical detection system
can also be used for combinatorial chemistry and high-throughput screening
applications. The new Low Temperature Evaporative Light Scattering Detector
(ELSD-LTII) is an easy-to-operate, universal detector that identifies analytes with
uniform sensitivity regardless of their spectroscopic properties. It is not a
spectroscopic detector. Instead, it removes the mobile phase through evaporation
and then makes a light scattering measurement of the dried analyte particles.





The ELSD-LTII is ideally suited for such applications as drug discovery, natural products development, combinatorial chemistry, and food and beverage. It will enable you to see all sample components, even semi-volatile compounds, down to the high picogram level.
The ELSD-LTII provides excellent performance during gradients for optimized separations and reduced run times. A unique cell design reduces band broadening to a level similar to UV-Vis detectors while its single mode, low-temperature operation (user defined from ambient 80°C) optimizes sensitivity for those analytes that are easily missed at higher evaporation temperatures typical of competing detectors.



A Universal Detector Detects all semi- and non-volatile analytes in your sample, including those transparent to other detectors.
Fully Gradient Compatible Handles any combination of volatile mobile phases and gradients for powerful separations and minimized run times.
Higher Sensitivity than RI and other ELSDs on the market The ELSD-LTII is 10 - 100X more sensitive than RI detectors for all samples and under all mobile phase conditions.
Detects all analytes, including semi-volatiles, at near-ambient evaporation temperatures Absolute temperature range (Ambient - 80°C) Commonly used working range (Ambient - 40°C) Semi-volatile analytes and compounds that thermally decompose are easily missed with competing detectors.
Accepts a wide range of mobile phase flows The ELSD-LTII displays excellent signal/noise characteristics over solvent flows from 100µL/min. to 4.0 mL/min.
Single-Mode operation Low temperature operation without accessories, separate operating modes. Most analyses are done using a common set of conditions (Gain 5; Temp 40°C; P 350kPa).
Time program air/nitrogen shutoff A time program method may be used to shut off the inlet gas, ending the problem of wasted gas after work is done.
Unique nebulizer/drift tube design offers protection from "fouling" The nebulizer and drift tube are separated by a glass chamber which protects the evaporation and detection stages from particle buildup. In competing detectors, such buildup contributes to background noise that cannot be solved without maintenance.
Stack other detectors on top of the ELSD-LTII The ELSD-LTII fits perfectly into the modular design of Shimadzu Prominence HPLC hardware. Dimensions: W250 x H450 x D550mm