XR-ODS II High-Separation Column

XR-ODS II High-Separation Column


The Shim-pack XR-ODS, which was developed with the aim of increasing the speed attained under standard column pressure conditions, has been joined by the Shim-pack XR-ODS II, which was developed in order to facilitate high-speed, high-separation analysis for a wider range of applications, such as those involving methanol mobile phases, by using a new long column.
The Shim-pack XR-ODS II is a high-separation analysis column that is suited to use in combination with the Nexera XR and that can also be used for high-temperature analysis.
Reducing the particle size of the packing material to an optimum level and unifying the particle diameter help suppress flow resistance and ensure excellent stability. As with the Shim-pack XR-ODS, quality control is performed in accordance with the standards indicated in the quality assurance document provided with the column.


XR-ODS II Lineup


Internal diameter (mm) Length (mm)
2.0 75 / 100 / 150
3.0 75 / 100 / 150


Particle diameter of packing material: 2.2 µm
Pore size: 8 nm
Pressure resistance: 60 MPa


Example of High-Separation Analysis

The results obtained by performing the high-separation analysis of polycyclic aromatics using the Nexera XR and the XR-ODS II are shown below. With general-purpose LC, the resolution, RS, for isomers of benzofluoranthene was 1.25, whereas with the Nexera XR, this was significantly increased to 2.12. With general-purpose LC, the analysis time was approximately 50 minutes, whereas with the Nexera XR, it was reduced to approximately half this. One advantage of increased speed is reduced consumption of mobile phase.


Analysis Conditions

Column: Shim-pack XR-ODS II (150 mm (L) x 3 mm (i.d.))
Column temperature: 40°C
Mobile phase: Water/acetonitrile = 35/65
Flow rate: 0.9 mL/min
Detection: 254 nm


The Nexera XR (pressure resistance: 66 MPa) also helps expand the range of analysis methods that can be used by, for example, allowing the use of water/methanol mobile phases and long columns, and enabling analysis to be performed at room temperature.
The results obtained by analyzing the catechins in green tea using a water/acetonitrile mobile phase and a water/methanol mobile phase are shown below. It can be seen that the separation selectivity, as represented by the elution order and the separation between components, differs between the methanol and acetonitrile systems. This example illustrates how the Nexera XR helps increase the range of available analysis methods, a feature that is useful for method development.


Analysis Conditions

Column: Shim-pack XR-ODS II (75 mm (L) x 3 mm (i.d.))
Column temperature: 40 °C
Mobile phases: Phosphate buffer solution / acetonitrile (top), phosphate buffer solution / methanol (bottom), gradient elution
Flow rate: 1.0 mL/min
Detection: 230 nm



For Research Use Only. Not for use in diagnostic procedures.


This page may contain references to products that are not available in your country.
Please contact us to check the availability of these products in your country.