SPME Arrows and Fibers
Shimadzu SPME Arrows
The SPME Arrow is a new technology for micro-extraction, combining trace level sensitivity with high mechanical robustness. The SPME Arrow has a large sorption phase surface resulting in two times higher sample throughput. The arrow-shaped tip allows smooth penetration of vial and injector septa. In contrast to traditional SPME fibers, the Arrow design fully protects the sorptive material, minimizing adverse influences and loss of analytes during transfer processes.
Features of SPME Arrows
• Bigger surface and faster extraction
• More surface provides more sorption phase
• Stainless steel and optimized construction
• Arrow formed tip
Benefits of SPME Arrows
• Higher sample throughput
• 10x higher sensitivity
• Longer lifetime
• Longer lifetime for injector septa

Color coded thread for manual or autosampler use
Stainless steel fiber with 20 mm long phase
Arrow shaped tip for smooth septa pentration
| Phase Type |
Outer
diam.
|
Phase
thickness
|
Color |
P/N
Pack of 1 pc
|
P/N
pack of 3 pcs
|
P/N
pack of 5 pcs
|
|---|---|---|---|---|---|---|
| 1. Polydimethylsiloxane (PDMS) |
1.1 mm | 100 µm | Red | 227-35305-01 | 227-35305-03 | 227-35305-05 |
| 2. Polydimethylsiloxane (PDMS) |
1.5 mm | 100 µm | Red | 227-35309-01 | 227-35309-03 | 227-35309-05 |
| 3. Acrylate | 1.1 mm | 100 µm | Grey | 227-35301-01 | 22735301-03 | 227-35301-05 |
| 4. Carbon Wide Range (WR)/PDMS |
1.1 mm | 120 µm | Light Blue |
227-35302-01 | 227-35302-03 | 227-35302-05 |
| 5. Carbon Wide Range (WR)/PDMS |
1.5 mm | 120 µm | Light Blue |
227-35306-01 | 227-35306-03 | 227-35306-05 |
| 6. Divinylbenzene (DVB)/PDMS |
1.1 mm | 120 µm | Violett | 227-35303-01 | 227-35303-03 | 227-35303-05 |
| 7. Divinylbenzene (DVB)/PDMS |
1.5 mm | 120 mm | Violett | 227-35308-01 | 227-35308-03 | 227-35308-05 |
| 8. DVB/Carbon WR/PDMS | 1.1 mm | 120 µm | Dark Grey |
227-35304-01 | 227-35304-03 | 227-35304-05 |
| 9. DVB/Carbon WR/PDMS | 1.5 mm | 120 µm | Dark Grey |
227-35307-01 | 227-35307-03 | 227-35307-05 |
| 10. Polydimethylsiloxane (PDMS) |
1.5 mm | 120 µm | Black | 227-35310-01 | 227-35310-03 | 227-35310-05 |
| SPME Arrow kit 1 for method development. Content: 1 pc. each of 1, 3 , 4, 6 ,10 |
227-35311-01 | |||||
| SPME Arrow kit 2 for method development. Content: 1 pc. each of 1, 3, 4, 6, 8 |
227-35312-01 | |||||
Liner for SPME Arrows
| Inner diameter [mm] | P/N pack of 3 pcs. | |
|---|---|---|
| For SSL injector of GC-2010 / GC-2030 | 1.3 | 227-35327-03 |
| 1.7 | 227-35328-03 |
Shimadzu SPME Fibers
SPME Fibers have been developed for fast and economical solvent-free analysis of samples. The fibers are offered with different coatings and film thicknesses. Their excellent extraction properties have been proven for many important applications.
Solid Phase Microextraction (SPME) is a solvent-free sample preparation technique. The fibers are either coated with a polymer, a sorbent or even both of them.
After the tip has punctured the septum of the vial the fiber is extended by pressing down the plunger. Once the sorbent is exposed, molecules of the analyte are sorbed. This results in a strong enrichment of the analyte relative to the sample. The fiber is then directly inserted into the injector for analysis.

Color coded thread for manual or autosampler use.
10 mm long fiber, coated with fused Silica
| Phase Type |
Phase
thickness
|
Color |
P/N
Pack of 1 pc
|
P/N
pack of 3 pcs
|
P/N
pack of 5 pcs
|
|---|---|---|---|---|---|
| 1. Polydimethylsiloxane (PDMS) | 7 µm | Green | 227-35313-01 | 227-35313-03 | 227-35313-05 |
| 2. Polydimethylsiloxane (PDMS) | 30 µm | Gold | 227-35314-01 | 227-35314-03 | 227-35314-05 |
| 3. Polydimethylsiloxane (PDMS) | 100 µm | Red | 227-35315-01 | 227-35315-03 | 227-35315-05 |
| 4. Acrylate | 85 µm | Grey | 227-35319-01 | 227-35319-03 | 227-35319-05 |
| 5. Carbon Wide Range (WR)/PDMS | 95 µm | Dark Blue | 227-35318-01 | 227-35318-03 | 227-35318-05 |
| 6. Divinylbenzene (DVB)/PDMS | 65 µm | Violett | 227-35317-01 | 227-35317-03 | 227-35317-05 |
| 7. DVB/Carbon WR/PDMS | 80 µm | Dark Grey | 227-35316-01 | 227-35316-03 | 227-35316-05 |
|
SPME Fiber kit 1 for method development.
Content: 1 pc. each of 1, 2 , 3, 4 ,5
|
227-35320-01 | ||||
|
SPME Fiber kit 2 for method development.
Content: 1 pc. each of 3, 4 , 5, 6, 7
|
227-35321-01 | ||||
Liner for SPME Fibers
| Inner diameter [mm] | P/N pack of 3 pcs. | |
|---|---|---|
| For SSL injector of GC-2010 / GC-2030 | 0.75 | 221-75196 |