AIMsight
Infrared Microscope
Infrared Microscope Maximizes Automation to Improve Microsample Analysis

The AIMsight infrared (IR) microscope is an automatic analysis system that maximizes automation to significantly improve efficiency of microsample defect analysis. This FT-IR microscope accurately measures micro targets by irradiating them with infrared rays, and then gauges the reflectance and transmittance from sample molecules. The AIMsight features several user-friendly functions, such as easy measurement range determination via a wide-field camera, automatic identification of measurement targets, automatic setting of measurement position, and automatic analysis via a contaminant analysis program, assuring that both beginners and specialists can feel confident from the very first analysis.
In addition to trace contaminant analysis and quality control for products such as chemicals, electronics, machinery, and transportation equipment, AIMsight also plays a big role in researching microplastics, tiny plastic particles that have a negative impact on the environment.
No liquid nitrogen required.
New detector capable of infrared microscopy measurements of minute samples.
Equipping the AIMsight Infrared Microscope with the TEC MCT (peltier cooled MCT) detector makes it possible to obtain infrared spectra without using liquid nitrogen. If more sensitivity is required, simply switch to the standard T2SL*1 detector in the software.
*1: Liquid nitrogen is required when using the T2SL.
AIMsight, the Analytical Intelligence logo, LabSolutions, IRXross, and IRTracer are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries.
Features
- 
              Equipped with a wide-field camera and an infrared microscope camera, it is capable of observations up to 10 × 13 mm, while the 330X digital zoom function enables observation of areas as small as 30 × 40 µm.
- 
              The AIMsight boasts the highest sensitivity in its class with a 30,000:1 S/N ratio. Operators can quickly acquire high-sensitivity data of micro measurement targets down to 10 µm in size. With the automatic contaminant recognition system, the analyst only needs to simply click one button for the software to automatically recognize targets.
- 
              After the data is acquired, it can be analyzed automatically by a contaminant analysis program equipped as standard. An original library of high hit ratios (optional) for analyzing contaminants in tap water and food products is also available.
Videos
- 
                  Infrared Microscope AIMsight SHIMADZU AlMs to provide analysis systems for all users. An automatic analysis system that can be used with confidence from your first analysis. Equipped as standard with enhanced functionality to support analyses 
 
             
             
             
             
                        