MALDI-8030
Dual-Polarity Benchtop Linear MALDI-TOF Mass Spectrometer
Affordable Class-leading Workhorse
MALDI-8030
The MALDI-8030 is the latest in a long line of MALDI-TOF products from Shimadzu. Instrument performance specifications is extended from those of the MALDI-8020 to cater for compounds best suited to analysis in negative ion mode. This dual-polarity, benchtop linear MALDI-TOF mass spectrometer delivers outstanding performance in a compact footprint, making it an ideal choice for today’s increasingly demanding laboratories.
Key features:
- Dual mode (positive/negative ion) MALDI-TOF
- 200 Hz solid-state laser, 355 nm
- Load-lock chamber for fast sample introduction
- UV laser-based source cleaning (patented)
- Flexibility
- Small footprint/benchtop design
- Quiet operation (<55 dB)
Best-in-class sensitivity and resolution
Dual mode instruments have traditionally been the instruments of choice in MALDI-TOF-based quality control (QC) and profiling workflows, and the MALDI-8030 is no exception. Peptides, proteins, polymers or oligonucleotides - the instrument is capable of delivering the performance required for QC applications. Research laboratories will also benefit from the MS capabilities of the instrument through the rapid mass-measurement of samples.

Features
-
Compatible with the FlexiMass series of microscope slide-format sample targets, these slides provide researchers with options depending on their experimental workflow.
-
To maintain instrument performance over time, the MALDI-8030 features wide-bore ion optics - a feature used on our existing MALDI-TOF products - which minimize the risk of source contamination over time, providing a robust platform.
-
As mass spectrometry moves into clinical laboratories, the MALDI-8030 is the perfect choice for researchers developing MALDI-based diagnostic methods. The system is designed and manufactured to ISO 13485:2016 quality management standards and is CE compliant.
Videos
-
Dual-Polarity Benchtop Linear MALDI-TOF Mass Spectrometer MALDI-8030
The MALDI-8030 is the latest in a long line of MALDI-TOF products from Shimadzu. Instrument performance specifications is extended from those of the MALDI-8020 to cater for compounds best suited to analysis in negative ion mode. This dual-polarity, benchtop linear MALDI-TOF mass spectrometer delivers outstanding performance in a compact footprint, making it an ideal choice for today’s increasingly demanding laboratories.
-
Benchtop MALDI-TOF Imaging Starter Kit
Compact, Affordable, MALDI Imaging: the application of Mass Spectrometry imaging is rapidly growing but is still only utilised by experienced scientists.
-
Rapid and Simple Sequence Confirmation of Nucleic Acid Therapeutics : MALDI
A MALDI-8020 benchtop MALDI-TOF mass spectrometer enabled a rapid measurement with simple sample preparation.
The instrument supports a rapid and easy sequence confirmation of nucleic acid therapeutics.