Constant-Temperature Measurement

Example of Measurement of Serum Cholinesterase Activity

The following accessories are used for biological
component measurement, enzymatic activity
measurement and reaction rate analysis for
which the sample must be kept at a constant
temperature. The figure shows an example in
which enzymatic activities are measured using
the CPS-240A cell positioner, 6 cell-thermoelectrical
temperature controller. The reactions in the six cells
were measured in parallel in a measurement time
of 200 seconds.

 

CPS-100 6-Cell Thermoelectrically Temperature-Controlled Cell Positioner

CPS-240A Cell Positioner,6 Cell-Thermoelectrical Temperature Controller

This accessory automatically switches

measurement between the six cells to
ensure efficient measurement. Accurate
temperature conditions can be maintained
without the need for circulation of cooling water.
 

  •  For UVmini, UV-1900i/2600i/2700i and 3600i Plus series

*) Square cells are not included in the standard package. Please purchase separately.

*) When used with the UV-1800/1900 series/2600 series/2700 series, a USB adapter CPS is required.

 
 
 

TCC-100 Thermoelectrically Temperature Controlled Cell Holder

TCC-240A Thermoelectrically Temperature Controlled Cell Holder

This easy-to-use cell holder uses a Peltier

element to electronically control the temperature,
so no external thermostatic bath or cooling water
circulation is required.
 

  •  For UVmini, UV-1900i/2600i/2700i and 3600i Plus series

*) Square cells are not included in the standard package. Please purchase separately.

*) The stirrer is optional. Please purchase separately.

 
 

Constant-Temperature Cell Holder

Constant-Temperature Cell Holder

This holder holds the sample cell at the desired,
uniform temperature by circulating constant-temperature
water. It accepts a pair of 10 mm square cells.
 

  •  For UVmini, UV-1900i/2600i/2700i and 3600i Plus series

*) When used on the UVmini series, the sample compartment unit is required.

 
 

S-1700 Thermoelectric Single Cell Holder

S-1700 Thermoelectric Single Cell Holder

This cell holder enables setting of the temperature

program to raise and lower the sample cell
temperature. The thermoelectric system
enables the sample temperature to be controlled
between 0 and 110 °C. A stirrer is also provided
to ensure uniform temperature distribution throughout the cell.
 

  •  For UVmini, UV-1900i/2600i/2700i and 3600i Plus series

*) Temperature is not controlled on the reference side.

*) Cooling water circulation is required for cooling the Peltier element. Though tap water can be used for cooling, the following conditions must be satisfied to elicit the maximum performance of the instrument. Use of a commercially available constant-temperature water circulator is recommended.

  • Cooling water temperature: 20±2 °C
  • Flow rate: 4.8 L/min or more

*) Cells are not provided. The following 10 mm square cell with a stopper (made by Hellma) is required.

Type Optical Path Length Minimum Required Sample Volume
110-QS-10 10 mm 3.5 mL
115B-QS-10 10 mm 400 µL
 

This page may contain references to products that are not available in your country.
Please contact us to check the availability of these products in your country.