Specifications

 

Seamless control of Shimadzu LC

Product

Description
Shimadzu LC Driver for Chromeleon™ 7.2 (for 1 system)

Compatible Units

Shimadzu LC driver compatible with Chromeleon™ 7.2 supports the following units.

# Unit Model
Nexera X2 Nexera XR Prominence i-Series
1 System Controller CBM-20A, CBM-20Alite LC-2030 Plus,LC-2030C Plus,LC-2030C 3D Plus
LC-2040C Plus,LC-2040C 3D Plus
LC-2030C LT Plus, LC-2040C LT Plus
LC-2040C MT Plus,LC-2040C 3D MT Plus
LC-2030,LC-2030C,LC-2030C 3D
LC-2040C,LC-2040C 3D
LC-2030C LT,LC-2040C LT
LC-2040C MT,LC-2040C 3D MT
2 Pump LC-30AD LC-20ADXR LC-20AD
LC-20AT
LC-20Ai
LC-20AB
3 Autosampler SIL-30AC
SIL-30ACMP
SIL20AXR
SIL-20ACXR
SIL-20A
SIL-20AC
SIL-20AHT (UFLC)
SIL-20ACHT (UFLC)
4 Rack Changer Rack Changer, Rack Changer C, Rack Changer II
5 Column Oven CTO-30A
CTO-30AS
CTO-20A
CTO-20AC
6 Detector SPD-M30A SPD-M20A RF-20A, RF-20AXS, RID-20A, AD input (option)
Detector SPD-20A, SPD-20AV
RF-20A, RF-20AXS
RID-20A
PC-55N (AD input)
7 Option Box Subcontroller VP, Option box VP  
8
Mobile Phase Flow Line
Switching Valve
FCV-10AL, FCV-10ALvp, FCV-11AL, FCV-11ALS, FCV-15AL
Low pressure 4 port valve built into LC-20ADXR/LC-30AD
FCV-11AL, FCV-11ALS
9 Flow Line Switching Valve FCV-12AH, FCV-13AL, FCV-14AH, FCV-32AH
FCV-12AH/FCV-14AH/FCV-32AH built into CTO-20A/CTO-20AC/CTO-30A
FCV-14AH, FCV-34AH
      Note: This is a 6-position, 7-port high-pressure flow line switching valve. Up to six columns can be switched for use.

Compatible ROM Versions

Shimadzu LC Driver Ver. 2.20 Compatible with Chromeleon™ 7.2 supports the units with the following ROM versions. Update the ROM if necessary.

Unit Model ROM Version
System Controller CBM-20A, CBM-20Alite 3.30 or later
Pump LC-30AD 3.00 or later
LC-20ADXR 2.02 or later
LC-20AD 1.12 or later
LC-20AT 1.10 or later
LC-20Ai 1.00 or later
LC-20AB 1.10 or later
Column Oven CTO-30AS 3.00 or later
CTO-30A 3.00 or later
CTO-20A / CTO-20AC 1.07 or later
Autosampler SIL-30ACMP 3.00 or later
SIL-30AC 3.00 or later
SIL-20A (HT, UFLC), SIL-20AC (HT, UFLC),
SIL-20AXR, SIL-20ACXR
1.25 or later
Rack Changer II 2.00 or later
Rack Changer, Rack Changer C 1.11 or later
Subcontroller Subcontroller VP (Option Box VP) 5.22 or later
Detector SPD-M30A 3.10 or later
SPD-M20A 2.00 or later
SPD-20A, SPD-20AV 1.11 or later
RF-20A, RF-20AXS 1.10 or later
RID-20A 1.00 or later
Analog input board (PC-55N) -
Integrated LC LC-2030, LC-2030C, LC-2030C 3D,
LC-2040C, LC-2040C 3D
2.10 or later
LC-2030C LT, LC-2040C LT 2.10 or later
LC-2040C MT, LC-2040C 3D MT 2.10 or later
LC-2030 Plus,LC-2030C Plus,LC-2030C 3D Plus
LC-2040C Plus,LC-2040C 3D Plus,
LC-2030C LT Plus,LC-2040C LT Plus,
LC-2040C MT Plus,LC-2040C 3D MT Plus
3.01 or later

Note: For Chromeleon™ 7.2-compatible Shimadzu LC driver Ver. 2.01 and later, authentication setting on the instrument is required during the installation of the driver. Check the compatible ROM versions of the CBM- 20A/lite and i-Series and configure settings for the instrument connection key.

 