Nexera series
Ultra High Performance Liquid Chromatograph Series
Faster Analysis Without Sacrificing Precision
It's important to use the most appropriate column in your LC system to achieve the highest efficiency and most accurate chromatograms. The Shim-pack series consists of a range of columns designed with the increased capabilities of Nexera in mind. The superior ruggedness of Shim-pack columns ensures a long lifetime even with demanding sample matrices.
Shim-packTM Velox
The superficially porous particle (SPP) technology allows for optimum separation and analysis times. The ranges of column types available enables you to choose the most appropriate column for each application.

Shim-packTM XR-ODS II & III
Although the Shim-pack XR ODS II has a particle size of 2.2 μm , it can be used up to a pressure of 60 MPa, making it appropriate for a wide range of analysis. The particle size of the XR-ODS III column has been reduced to 1.6 μm . With a maximum pressure of 100 MPa, it achieves high separation even with a short column length. These columns are suitable for shortening analysis times while taking full advantage of the high separation power of UHPLC.

Shim-packTM GIS/GIST/GISS
The Shim-pack GIS/GIST/GISS series lineup includes columns with particle sizes ranging from 5 μm , appropriate for HPLCs, to 2 μm , appropriate for UHPLCs. With a variety of substrates available, they are ideal for method development.
GIS Series:
HPLC columns packed with a high-purity silica gel material as a base. With high particle uniformity to secure the mobile phase path, these columns are ideal for low-pressure analysis.
GIST Series:
An increase in the inertness of the silica results in improved peak shapes and ruggedness. Can be used in pH 1-10 environments. Easy to use for a wide range of chemicals and environments.
GISS Series:
Adding to the advantages of the GIST series, a faster elution time has been achieved to provide even sharper peaks.
Extract the Smallest of Shoulder Peaks

The i-PeakFinder tool can automatically recognize peaks even in complex chromatograms with high noise, and accounts for baseline drift for higher integration accuracy. Adjustable parameters in i-PeakFinder, such as peak detection threshold, allow the user to detect smaller peaks. In addition, the i-PDeA II function can quantify peaks that cannot be completely separated by a column. Separate peaks by simply specifying the time and wavelength in LabSolutions.


Consistent Peak Splitting
Manually setting the baseline for fused peaks is time-consuming, and the peaks may be split differently depending on the user. The i-PeakFinder has adjustable parameters for different analyses, allowing the consistent application of the best baseline in each situation.

Dynamic Range Extension Function for Accurate Calibration
i-DReC is a new analytical method that significantly extends the dynamic range. It enables the analysis of hight concentration compounds without diluting them, and ensures a correct calibration curve.