Shimadzu GC Driver for Waters Empower - Specs
Controllable Hardware
GC unit | Nexis GC-2030, GC-2010, GC-2010 Plus, GC-2010 Pro, GC-2014, GC-2014C |
---|---|
Options | AOC-30i autoinjector, AOC-20i (Plus) autoinjector, AOC-20s (U) autosampler, HS-20 (NX) headspace sampler, HS-10 headspace sampler |
Nexis GC-2030
Sample injector | SPL-2030, WBI-2030, OCI-2030, PTV-2030, SINJ-2030 |
---|---|
Detector | FID-2030, TCD-2030, ECD-2010 Exceed, FPD-2030, FTD-2030, BID-2030, SCD-2030, PTCD-2030 |
Advanced flow technology | Backflush, detector splitting, detector switching, heart-cut system |
Additional temperature controller | AUX temperature control unit |
Additional flow controller | APC (3 auxiliary channels), APC (1 auxiliary channel) |
Options | Gas Selector Low-temperature control solenoid valve set: CRG-2030 External equipment control relay PRG-2010 Plus, PRG BOX |
· Dual-injection systems are not supported.
· Up to four Shimadzu GC units can be controlled on one data acquisition server (e.g. LAC/E32).
· Both the Shimadzu LC driver and Shimadzu GC driver for Empower can be installed on one computer or data acquisition server.
· A Shimadzu GC system and Agilent GC system cannot be connected to the same data acquisition server (e.g. LAC/E32) at the same time. Provide a data acquisition server dedicated for the Shimadzu GC system.
GC-2010(Plus/Pro) , GC-2014(C)
Sample injection port | GC-2010 (Plus/Pro): SPL-2010 (Plus), WBI-2010 (Plus), OCI/PTV-2010 (Plus) GC-2014 (C) : SPL-2014, WBI-2014, DINJ-2014, SINJ-2014 |
---|---|
Detector | GC-2010 (Plus/Pro): FID-2010 (Plus), TCD-2010 (Plus), ECD-2010 Exceed, ECD-2010 (Plus), FPD-2010 (Plus), FTD-2010 (Plus), BID-2010 Plus GC-2014 (C) : FID-2014, TCD-2014, ECD-2014, FPD-2014, FTD-2014(C) |
Additional temperature controller | AUX temperature control unit |
Additional flow controller | APC (3 auxiliary channels), AMC (2 auxiliary channels) Note: AMC is an option for the GC-2014. |
Options | Low-temperature control solenoid valve set: CRG-2010 External unit control relay: PRG-2010 (Plus), PRG BOX |
· Dual-injection systems are not supported.
· Up to four Shimadzu GC units can be controlled on one data acquisition server (e.g. LAC/E32).
· Both the Shimadzu LC driver and Shimadzu GC driver for Empower can be installed on one computer or data acquisition server.
· A Shimadzu GC system and Agilent GC system cannot be connected to the same data acquisition server (e.g. LAC/E32) at the same time. Provide a data acquisition server dedicated for the Shimadzu GC system.