Nexera UC
The Nexera UC SFE – SFC – MS platform unifies quick and easy on-line sample preparation with state-of-the-art chromatographic analysis and high sensitivity detection. Nexera UC improves your analytical workflow through an unprecedented combination of Supercritical Fluid Extraction (SFE) sample preparation with Supercritical Fluid Chromatography (SFC) analysis. The system enables a wide range of applications from isomers and chiral substances in food or natural products, analysis of biomarkers from dried blood spots and analysis of polymer additives in plastics and packaging.
Nominations and Awards
Nomination for Scientists´ Choice Award 2016

Winner Pittcon Editors’ Gold Award 2015

| Conventional LC/MS and GC/MS face these challenges. | Nexera UC provides uncompromising solutions. | |
|---|---|---|
![]() |
Time-consuming sample preparation | Fully automated on-line sample preparation and analysis |
| Degradation of labile compounds during sample preparation |
Even labile compounds can be analyzed without degradation | |
| Low abundant peaks hidden in noise | Unified speed of analysis, sensitivity, and resolution |
Just another chromatographic technique... or the only technique you'll need?

Nexera UC improves your analytical workflow by utilizing a completely new separation technology, Unified Chromatography, which unites sample separation, analysis with various separation modes, and high-sensitivity detection.
Solutions provided by Nexera UC
| Isomeric compounds | Chiral analysis | Analysis of biomarkers from dried blood spots | Quick start of cleaning validation in pharmaceutical industry | Analysis of polymer additives |
![]() |
![]() |
![]() |
![]() |
![]() |
Comparison of QuEChERS sample preparation and Nexera UC in the analysis of residual pesticides
A typical sample preparation takes 35 minutes and requires several manual steps. With Nexera UC, the same sample can be ready for on-line SFE/SFC analysis in as little as five minutes with only a few simple sample preparation steps.

* "Miyazaki Hydro-Protect", Patented in Japan No.3645552
Hundreds of compounds are simultaneously analyzed with Nexera UC. These include pesticides that are usually analyzed with LC and LC/MS/MS or GC and GC/MS/MS. Nexera UC enables analysis of compounds over a wide polarity range.

Analysis of Compounds with Wide Polarity Range
For Research Use Only. Not for use in diagnostic procedures.