Peripheral Equipment
Autosampler AS10 (For automatic analysis of 60 samples)
Autosampler AS10Multiple samples can be analyzed successively. The turntable results in a short path length for sample injection, which can reduce the rinse time. Vials: 60 15mL vials
8 50mL vials
Size: W290 × D508 × H300 mm (excluding arm)
Power supply: Singlephase 100 V, 50/60 Hz, 100 VA
Note: Requires separate power cord.
Note: An additional rinsing port is optional (There is no automatic solvent supply). Rinsing Port Expansion Kit for AS10.
ASX-280 Autosampler (For automatic analysis of 120 samples)
ASX-280 AutosamplerVials:
10 50-mL vials (standard samples) or 120 14-mL vials
80 20-mL vials (rack sold separately)
42 50-mL vials (rack sold separately)
Size: W355 x D550 x H620 mm (include sample probe), W90 x D180 x H60 mm (rough dimensions of power supply unit)
Power supply: 100-240 V AC, 47-63 Hz, 1.9A
Weight: 8.1 kg (main unit)
Note: Requires an ASX Connection Kit ICPMS-2030.
ASX-560 Autosampler (For automatic analysis of 240 samples)
ASX-560 AutosamplerVials:
10 50-mL vials (standard samples) or 240 14-mL vials
160 20-mL vials (rack sold separately)
84 50-mL vials (rack sold separately)
Size: W580 x D550 x H620 mm (include sample probe), W90 x D180 x H60 mm (rough dimensions of power supply unit)
Power supply: 100-240 V AC, 47-63 Hz, 1.9 A
Weight: 11.7 kg (main unit)
Note: Requires n ASX Connection Kit ICPMS-2030.
HVG1 Hydride Generator For highsensitivity analysis of As, Se, and Sb
HVG1 Hydride GeneratorThis unit uses nascent hydrogen generated from decomposition of sodium borohydride to vaporize elements in samples by reduction and then introduce only the gas phase into the plasma. This enables measurements with about 50 times higher sensitivity. Note: Requires a separate HVGICPMS connection kit and liquid waste pump
Cooling Water Circulator Set
Cooling Water Circulator SetSize: W377 × D500 × H615 mm Power supply: Singlephase
200 V, 50/60 Hz, 2 kVA
Weight: 43 kg
Note: Used to cool the main unit. Note: Requires a separate chiller connection kit.
Note: Requires tetoron braided hoses for coolant water supply and drain. Order in meter units for the overall length.
Automatic Internal Standard Addition Kit
This kit is used for inline mixing of measurement sample and internal standard solutions and introducing the mixtures into the ICP system.
HFS5 Hydrofluoric Acid Sample Injection System
This system includes a torch, chamber, extension tube, nebulizer, drain, and their corresponding accessory parts. If purchasing a new system, order this kit and an S2 orifice assembly. Used to directly inject samples that contain hydrofluoric acid. The nebulizer, chamber, and drain system are made using fluoropolymer materials and the injector unit on the torch is made using alumina.
Organic Solvent Injection System
To introduce organic solvents, a mixture of argon and oxygen gases (70% Ar and 30% O2) is injected into the interface unit to prevent precipitation of carbon (C) by the organic solvent. This system includes a Quadruple Torch for Organic Solvents, ICPMS, drain, and their corresponding accessory parts.
Exhaust Duct Connection Adapter
Noise Reduction Box for Rotary Pumps
Note: Requires Noise Reduction Box Connection Kit for Noise Reduction Box for Rotary Pumps.
For Research Use Only. Not for use in diagnostic procedures.