Shimadzu GC Driver for Waters Empower
Gas Chromatograph for versatile applications
Injection Units DINJ-2014
Dual Packed Injection Unit
Designed for Dual FID and TCD analyses. Because two flow paths are handled
using one temperature control port, these count as one heated zone.
SPL-2014 Split/Splitless Injection Unit
Standard unit for high-speed analysis with a narrow bore column. The gas saver function restricts the total gas used. High-pressure injection standard
SINJ-2014 Single Packed Injection Unit
This is a specialized sample injection unit for use with ECD or other high sensitivity detectors.
WBI-2014 Direct Injection Unit
Incorporates a septum purge flow path to restrict solvent tailing. Sharing glass inserts with splitless analysis simplifies parts requirements (patented).
FID-2014
Flame Ionization Detector
Automatic ignition and re-ignition functions are standard. By mounting an APC or solenoid valve unit, a feedback function cuts off gas supply when the hydrogen flame is extinguished. Generally used for detection of organic compounds with a hydrogen carbon bond. Single and dual FID's arele. availa
TCD-2014
Thermal Conductivity Detector
The TCD-2014 is a semi-diffusion type cell reducing contamination and increasing cell lifetimes. Incorporates an automatic filament protection circuit. The TCD-2014 is used for analysis of inorganic gases and concentrated organic compounds.
ECD-2014
Electron Capture Detector
This cell is very similar to the ECD-14; so spare radiation sources can be shared. This detector is used for analysis of electrophillic compounds. Improved cell insulation and reduces contamination achieving higher sensitivity.
FPD-2014
Flame Photometric Detector
The FPD-2010, the nozzle system was updated to provide support for packed column analysis while maintaining its high sensitivity. The FPD-2014 is compact with a high maximum temperature (350deg.C). This detector is used for analysis of organic sulphur compounds and organic phosphorus compounds such as residual pesticides and malodorous components.
FTD-2014
Flame Thermionic Detector
Packed column analysis is supported by the FTD-2014 using the FTD-14 mechanism and collectors from both the FTD-14 and -17. Used for analysis of organic nitrogen compounds and organic phosphorus compounds such as residual pesticides.
FTD-2014C
Flame Thermionic Detector
This specialized capillary-type detector employs the FTD-2010 mechanism. Used for analysis of organic nitrogen compounds and organic phosphorus compounds such as residual pesticides. The new collector construction allows replacement without tools. An optional alkali source regeneration kit recoats the bead reducing running costs.
HS-10
AOC-20i/AOC-20s
GC Consumables
SH-I-1MS
SH-I-5MS
SH-I-1HT
SH-I-5HT
SH-I-5Sil MS
SH-I-XLB
SH-I-17
SH-I-35Sil MS
SH-I-17Sil MS
SH-I-PAH
SH-I-624Sil MS
SH-I-1301Sil MS
SH-1
SH-1 PONA
SH-5
SH-5MS
SH-20
SH-35 / SH-35MS
SH-50
SH-65
SH-65TG
SH-1301
SH-624
SH-1701
SH-200 / SH-200MS
SH-225
SH-440
SH-502.2
SH-2330
SH-2560
SH-Wax
SH-PolarWax
SH-1614
SH-OPP / SH-OPP2
SH-CLP / SH-CLP II
SH-VMS
SH-Volatil Amin
SH-PCB
SH-VRX
SH-FAME
SH-BAC Plus 1 / SH-BAC Plus 2
SH-5 Amine / SH-35 Amine
SH-PolarD
SH-PolarX
SH-PolarWAX MS
SH-Alumina BOND Na2SO4
SH-Alumina BOND KCL
SH-Msieve 5A
SH-Q-BOND
SH-U-BOND
SH-MetalX-1
SH-MetalX-1HT SimDist
SH-MetalX-5
SH-MetalX-1701
SH-MetalX-WAX
SH-MetalX Biodiesel TG
SH-I Guard Retention Gap Columns
SH-Particle Trap (for PLOT columns)
SH-IP Guard Columns
SH Guard Columns Polar Deactivation
Integrated Guard Columns
SH-MetalX-Siltek Guard Column
SH Guard Columns Base Deactivated
Method Optimization System Triple Capillary Column GC
Gas Filter
Refinery Gas Analysis
Natural Gas Analysis
Transformer Oil Gas Analysis
Impurity Analysis in Bulk Gas
Trace Sulfur Analysis
Other Liquid / Gas Samples
Green House Gas Analysis
LabSolutions LCGC