Prominence UFPLC

Beyond High-Purity Purification Prominence UFPLC
 

When developing new drugs, structural analysis of impurities and metabolites is a critical process that cannot be avoided. However, structural analysis after synthesis or purification by preparative LC is time-consuming and recovering high-purity samples is very difficult. Therefore, as a solution to this problem, Shimadzu offers the Crude2Pure system, which recovers target compounds in high-purity powder based on a revolutionary purification method that involves using two purification systems. The Ultrahigh-Speed Preparative Purification System, Prominence UFPLC system, the newest addition to Shimadzu’s family of purification systems, inherits the same purification method as the Crude2Pure, but handles all steps, from fractionation to purification, within a single system, so that target compounds can be recovered in high-purity solution.

 

 

One System Handles It All

 

 

A New Solution for Preparative Purification in Operations

 

Ranging from Analysis to Semi-Preparative Purification
 

The Prominence UFPLC system uses the LC-20AD/AP solvent pump for preparative purification. The LC-20AD/AP is able to deliver low-pressure gradients for supporting applications ranging from analysis to semi-preparative-scale operations. Fractionation, concentration, purification, and recovery processes are fully automated to provide a new online purification solution.

 


*1 Total time depends on the combination of Prominence UFPLC and Evaporation system (provided preparative time is 30 min). Note: Contact your Shimadzu sales representatives for details about configurations, specifications, etc.

 

 

Building systems appropriate to your purposes

Prominence UFPLC Standard System

 

This is the most basic Prominence UFPLC system. Automated Preparative Purification is available when there is only one target compound.

 

 

Prominence UFPLC Advanced System
 

This is a fully automated system to purify several compounds, including the main target compound, residual substance and impurities (five kinds at max.), from a preparative sample.

 

 

Recover High-Purity Liquid by Eliminating Solvent Components
 

Easily Eliminates Previously Difficult-to-Eliminate Counter Ions and Low-Volatility Solvents
 

Mobile phases used for HPLC separation for pharmaceutical components sometimes include compounds like trifluoroacetate that form counter ions. If such components are included in preparative fractions, they can cause problems during drying or testing after purification. However, the Prominence UFPLC system is able to easily eliminate such components that may be contained in fractionated liquids. Depending on the elimination method selected, target compounds can also be recovered in freebase form, in addition to eliminating components from the mobile phase.

 

 

Structural analysis without pretreatment
 

Two 0.1% TFA propranolol solutions were prepared, with one treated as a freebase, and then the solvent evaporated. The 19F NMR spectra from these two samples are shown. The TFA peaks are much smaller for the sample with freebase treatment than for the untreated sample, which indicates that the process was effective in eliminating TFA.

 

 

Easy-to-Operate Dedicated Software
 

With the dedicated Purification Solution software, the analysis status can be quickly confirmed at a glance using the peak tracking function.

 

 

Variety of Fractionation Modes
 

To ensure reliable fractionation and purification of precious samples, the Purification Solution software offers three fractionation modes.

 

 

 

 

Automatic Fractionation Mode
 

In this mode, the software automatically identifies peaks and collects fractions based on parameter settings. Fractions can also be simulated in advance by opening acquired data using the simulation function, which optimizes parameter settings. It also supports calculating multiple theoretical detector signals.

 

 

 

Manual Fractionation Mode
 

In this mode, the mouse pointer is used to select peaks for fractionation while viewing the window. When concentrating a sample by reinjecting it multiple times, the function remembers the timing of the first fraction, so that the fraction is automatically performed at the specified time for each injection thereafter.

 

 

 

Time-Specified Fractionation Mode
 

This mode collects fractions based on the retention times in previously acquired data. It is ideal for routinely performed preparative purification processes.

 

For Research Use Only. Not for use in diagnostic procedures.

This page may contain references to products that are not available in your country.
Please contact us to check the availability of these products in your country.