Specifications
Products
| Descriptions | Notes |
|---|---|
| e LAC/E32 16 System | 2 or 4 licenses can be selected |
| Shimadzu LC control license | 1 license only |
| Shimadzu LC Driver for Waters Empower First Year Support Plan Single (for 1 system) | For either personal or enterprise use |
| Shimadzu LC Driver for Waters Empower First Year Support Plan Multi (for 4 systems) | For either personal or enterprise use |
- * If using an Empower enterprise system, Shimadzu’s dedicated LAC/E32 server is required.
- * Up to 4 Shimadzu LC/GC systems can be controlled from one computer or LAC/E32 intake server. However, if 1 or 2 PDAs are connected, this reduces the number of GCs/LCs that can be connected by 1 or 2 respectively.
- * To control a Shimadzu LC, a Shimadzu LC control license is required in addition to a LAC/E32 system control license.
Supported devices
| Unit | Model Name | Minimum required ROM Version |
|---|---|---|
| System Controller | SCL-40, CBM-40, CBM-40lite | 1.20 |
| Pump | LC-40D, LC-40D XR, LC-40B XR | 1.02 |
| LC-40D XS, LC-40D X3, LC-40B X3 | 1.02 | |
| Column Oven | CTO-40C | 1.00 |
| CTO-40S | 1.00 | |
| Autosampler | SIL-40, SIL-40C, SIL-40 XR, SIL-40C XR SIL-40C XS, SIL-40C X3 | 1.05 |
| Plate Changer | 1.04 | |
| Detector | SPD-40, SPD-40V | 1.02 |
| SPD-M40 | 2.00 | |
| RF-20A, RF-20AXS | 2.02 | |
| CDD-10Avp | 5.10 | |
| RID-20A | 2.04 | |
| AD board | - | |
| Mobile phase monitor | MPM-40 | 1.02 |
| Mobile phase flow path switching valve | LPGE Unit, FCV-11AL, FCV-11ALS, UV recycle valve | -*1 |
| High-pressure flow path switching valve | FCV-0206, FCV-0607, FCV-0206H FCV-0607H, FCV-0206H3, FCV-0607H3 | -*1 |
| FCV-DR | 1.02 |
-
*1 These parts can only be attached to the CTO.*2 It is not possible to use older versions of the above products (such as the LC-30AD pump) with this system.
| Unit | Model Name | Minimum required ROM Version |
|---|---|---|
| System Controller | CBM-20A, CBM-20Alite | 3.50 |
| Pump | LC-30AD | 3.21 |
| LC-20AD | 2.11 | |
| LC-20ADXR | 1.23 | |
| LC-20AT | 2.01 | |
| LC-20AB | 2.02 | |
| LC-20Ai | 1.00 | |
| Column Oven | CTO-30A | 3.11 |
| CTO-20A, CTO-20AC | 2.10 | |
| CTO-10AS VP | 5.28 | |
| Autosampler | SIL-30AC | 3.20 |
| SIL-30ACFV | 3.20 | |
|
SIL-20A, SIL-20AC (including HT and UFLC models) |
1.28 | |
| SIL-20AXR, SIL-20ACXR | 1.28 | |
| Rack Changer II | 2.00 | |
| Rack Changer, Rack Changer C | 1.11 | |
| Sub Controller | Sub Controller VP | 5.22 |
| Option Box VP | ||
| Detector | SPD-20A, SPD-20AV | 2.03 |
| RF-20A, RF-20AXS | 2.02 | |
| RF-10AXL | 3.33 | |
| RID-20A | 1.02 | |
| CDD-10Asp, CDD-10Avp | 5.10 | |
| SPD-M20A | 2.03 | |
| SPD-M30A | 4.02 | |
| SPD-30AM | 4.01 | |
| AD Input Board (PC-55N) | - | |
| Mobile Phase Flow Line Switching Valve |
FCV-10AL / FCV-10ALvp / FCV-11AL / FCV-11ALS / FCV-15AL /Switching Valve LC-20AD / LC-20AT / LC30-AD |
- |
| High-Pressure Flow-Line Switching Valve | FCV-12AH / FCV-13AL / FCV-14AH | - |
|
FCV-12AH / FCV-14H / FCV-32AH built into CTO-20A / CTO-20AC / CTO-30A |
- |
- * 4 systems maximum with no PDA or 3 systems with single PDA or 2 systems with 2 PDA (per LAC/E).
- * CBM-20A lite will not support analogue data acquisition. Please use CBM-20A with a PC-55N AD board if analogue signal is acquired.
- * LC-2010 can connect on Empower 3 FR3 or earlier versions.
Configuration examples
Empower Personal (Stand-alone type)
Empower Personal is a stand-alone type configuration. A PC includes a database and data acquisition functions. A single PC is connected directly to LC system(s), and a maximum of 4 LC systems can be controlled.

Empower Enterprise (Network type)
Empower Enterprise is a client-server (C/S) system, which allows any client PC on the network to control any HPLC. HPLC control and data acquisition are done through an acquisition server called LAC/E32, and the acquired data are stored in the database server. Analysis instructions and LC instrument status monitoring are performed from a client PC. Each Shimadzu LC system is controlled by TCP/IP protocol from a PC. If any problem occurs in a LC system on the network, other LC systems in operation are not affected.

*EmpowerTM and Empower3 are trademarks of Waters corporation