(U)HPLC systems Shimadzu

 

 

Sustainability in every peak

Shimadzu’s compact i-Series of liquid chromatographs bring together years of proven performance and customer-driven enhancements in an eco-friendly design, aligning with modern sustainability goals. Engineered for intuitive operation, they streamline sample preparation, automate continuous analysis, and support remote monitoring for effortless efficiency. Innovative Analytical Intelligence features ensure reliable, trouble-free operation while significantly reducing energy consumption. Delivering consistent, high-quality results, the i-Series empowers confidence in every run while minimizing environmental impact.

  • Discover the latest i-Series of compact (U)HPLC systems

    • Reliability you can trust
      Built for an exceptional roboustness, the system ensures consistently accurate analytical results with advanced Analytical Intelligence features like auto-diagnosis and error prevention, minimizing downtime for trouble-free operation
    • Sustainable Innovation
      Designed with the environment in mind, it reduces energy consumption by 21.5%, incorporates 73% recycled materials and uses bio-based packaging to deliver high performance while lowering environmental impact
    • Compact and User-Friendly
      With intuitive operation, automation and minimal maintenance, the system installs 60% faster, features longer-lasting consumables and streamlines workflows for greater efficiency and ease of use

     
  • (U)HPLC systems Shimadzu

 

 


 

See how the i-Series fits your workflow — talk to our team!

 


 

 

 

Watch: Introduction to Shimadzu's i-Series LC System

    • Benefit from the eco-friendly design, reducing environmental impact while enhancing productivity
    • Streamline your workflow with automation powered by Analytical Intelligence™, including bubble detection and peak deconvolution
    • Maximize your lab’s efficiency and throughput with this compact, innovative system designed for exceptional performance
    • Simplify troubleshooting and ensure reliable operation using intuitive tools like maintenance reminders and QR codes

     

 

 

 

Features

Confidence in every run – Intelligence and sustainability, built in

 

 
(U)HPLC systems Shimadzu

 

Shimadzu integrates sustainability at every level, from design to operation. Select components are crafted from chemically recycled plastics, reducing reliance on petroleum and limiting carbon dioxide emissions. Smarter, optimized packaging—lighter, smaller, and more efficient—cuts shipping costs while minimizing environmental impact. Durable parts extend replacement intervals, reducing analysis interruptions and improving instrument uptime for greater operating efficiency. Additionally, the auto-shutdown function significantly lowers power consumption in standby mode, cutting energy use by 95% or more compared to regular standby settings.

 

Intelligence

The latest i-Series models offer three key functionalities for diagnosis, prevention, and system restoration to maintain analytical robustness.

Prevention

(U)HPLC systems Shimadzu

 

 

 To safeguard against column deterioration from sudden pressure spikes, it’s essential to gradually increase the mobile phase flow rate as the column temperature rises. The FlowPilot flow rate control feature seamlessly synchronizes with the column oven temperature, providing optimal protection against abrupt pressure changes during automatic equilibration.

Diagnosis

(U)HPLC systems Shimadzu

 

 

During the pump's flow path check, it identifies any malfunctions in the check valves, while the autosampler's flow path check detects contamination and blockages in the injection system. Additionally, UV and PDA wavelength checks assess detector lamp performance prior to analysis, guaranteeing that the entire system is in peak condition before starting any analytical procedures.

 

Recovery

(U)HPLC systems Shimadzu

 

 

Pump pulse detection and the Auto Recovery function effectively manage air bubbles that can disrupt flow and impact chromatograms. The system continuously monitors the pressure curve, automatically pausing the run if significant fluctuations are detected. It then initiates a corrective purge and re-equilibration before restarting the batch from a defined position. This intelligent process helps eliminate data loss due to air bubbles and pressure fluctuations, ensuring reliable results during long sequences.

Column Management

(U)HPLC systems Shimadzu

 

 

Maintaining a comprehensive record of column usage history is essential for high data reliability, and the intelligent Column Management Platform (iCMP)* offers an integrated solution for tracking this information. By enhancing usability and data integrity, the iCMP allows users to easily monitor column performance and make informed decisions about their analytical processes.

*Sold separately. Only available with LabSolutions CS.

 

Innovation

(U)HPLC systems Shimadzu

 

With FlowPilot's automated flow rate control, mobile phase monitoring, and Analytical Intelligence-driven functionality, the latest i-Series systems represent a significant advancement in laboratory automation. Integrated with LabSolutions Direct software, they allow for comprehensive management of everything from system startup to analysis shutdown through automated processes or remote control and monitoring. These innovative workflows incorporate the expertise of seasoned analysts, ensuring consistent data acquisition over extended periods. By minimizing manual labor in the lab, this system enhances overall productivity and reliability, setting a new benchmark for efficiency in analytical processes.

 

Intuition

(U)HPLC systems Shimadzu

 

The intuitive user interface mirrors the system’s flow path, providing users with a clear visualization of the operating status. Methods can be created or edited directly from this screen, streamlining operations for enhanced efficiency. Designed with user-friendliness in mind, the interface allows even first-time liquid chromatography users to begin their work with minimal training.

(U)HPLC systems Shimadzu

 

 

The auto-validation function enables users to easily verify instrument condition through a standardized procedure. It automatically checks essential performance metrics, including solvent delivery stability, wavelength and absorbance accuracy, gradient precision, and signal drift or noise. Additionally, the built-in instrument check conducts routine pre-run inspections and generates a detailed report featuring self-diagnostic results and consumables usage, tracking solvent volume delivered, total injections by the autosampler, and lamp operating hours. All auto-validation results are centrally managed, allowing for quick and accurate assessments of instrument status.

 


 

Request a quote today — talk to our team!

 


 

 

Explore more solutions for your analysis

Shimadzu offers a broad range of LC and SFC solutions in both analytical and preparative scale, with a variety of optical or MS detectors and suitable software solutions to meet customer requirements.

 

 

 

 

i-Series Features in Action: Technical Video Series

Videos

Read more
Show Less
Learn More
{"title":"Downloads","description":"Download the latest brochure.","source":"product","key":4554,"max":30,"filter_types":["brochures"],"link_title":"View other Downloads","link_url":"","pdf_links":[]} {"title":"Applications","source":"product","key":4554,"max":3,"filter_types":["applications","application_note","posters"],"link_title":"Learn more","link_url":"\/products\/liquid-chromatography\/hplcuhplc\/i-series\/applications.html","config_list":[],"page_links":[],"column_title":"Documents"} {"title":"Technical Documents","source":"product","key":4554,"max":3,"filter_types":["technical","technical_reports","white_papers","primers"],"link_title":"Learn more","link_url":"\/products\/liquid-chromatography\/hplcuhplc\/i-series\/applications.html#tbaleAnchor_technical","config_list":[],"page_links":[],"column_title":"Documents"} {"title":"Manuals","source":"product","key":4554,"max":3,"filter_types":["manuals"],"link_title":"Learn more","link_url":"\/products\/liquid-chromatography\/hplcuhplc\/i-series\/applications.html#tbaleAnchor_manual","config_list":[],"page_links":[],"column_title":"Documents"}

Sustainability initiatives