Syringes for AOC-6000 Series

Smart Syringes for AOC-6000 Plus

A built-in Smart Chip in the head of each syringe stores all process data of the syringe during its lifetime to reach highest precision and process safety.

Shimadzu adds additional process safety and effectivity to your process with new smart technology. Each Smart Syringe is equipped with its own chip for storing parameters and usage. The new Shimadzu AOC-6000 plus reads the smart chip of the syringe and displays the information for the device such as first use and stroke counts. Every syringe can be traced over its complete lifetime.

Features Benefits
Simple and fast The system reads all syringe parameters from its chip
ID identification Lifetime tracking by specific ID
Syringe history All data is stored on the chip: stroke numbers, first use, temperatures
Color coded Easy identification of syringe type

Standard recommendation:
227-35352-02: 10 µl syringe with metal plunger for standard application
227-35353-02: 10 µl syringe with PTFE tipped plunger for gas and viscous samples, minimized plunger bending
227-35353-01: 10 µl syringe with 26G for sample preparation steps
227-35359-01: 2.5 mL syringe for headspace analysis

 

Specifications & Ordering Information

P/N Syringe Volume PTFE Tipped Plunger Needle Length
(mm)
Needle
Gauge
Needle
Tip
227-35352-02 10 µl - 57 23S Cone
227-35353-02 10 µl 57 23S Cone
227-35353-01 10 µl 57 26S Cone
227-35361-02 10 µl 85 26S Cone
227-35361-01 10 µl - 85 26S Cone
227-35354-01 25 µl 57 26S Cone
227-35354-02 50 µl 57 26S Cone
227-35355-01 100 µl 57 26S Cone
227-35362-01 100 µl 85 26S Cone
227-35356-01 250 µl 57 26 Cone
227-35358-01 1 mL 57 23 Cone
227-35385-01 1.3 mL
For ITEX
without needle ./. ./.
227-35359-01 2.5 mL
For Headspace
65 23 Side Hole Dome

All syringes have fixed needles.

 
 
 

Syringes for AOC-6000

 

 

Standard recommendation:
227-37167-01: 10 µl syringe with metal plunger for standard application
227-37168-01: 10 µl syringe with PTFE tipped plunger for gas and viscous samples, minimized plunger bending
225-19744-03: 10 µl syringe with 26G for sample preparation steps
225-19744-11: 2.5 mL syringe for headspace analysis

 
 

Specifications & Ordering Information

P/N Syringe Volume PTFE Tipped Plunger Needle Length
(mm)
Needle
Gauge
Needle
Tip
225-19744-01 1 µl For Headspace 57 23 Cone
227-37166-01 5 µl - 57 23 Cone
225-19744-02 5 µl - 57 26 Cone
227-37160-01 5 µl - 85 23 Cone
227-37167-01 10 µl - 57 23 Cone
227-37168-01 10 µl 57 23 Cone
225-19744-03 10 µl - 57 26 Cone
225-19744-04 10 µl 57 26 Cone
227-37161-01 10 µl - 85 23 Cone
227-37162-01 10 µl 85 23 Cone
225-19744-05 25 µl 57 26 Cone
227-37163-01 25 µl 85 23 Cone
225-19744-06 50 µl 57 26 Cone
227-37164-01 50 µl 85 23 Cone
227-37169-01 100 µl 57 23 Cone
225-19744-07 100 µl 57 26 Cone
227-37165-01 100 µl 85 23 Cone
227-37170-01 250 µl 57 23 Cone
225-19744-08 250 µl 57 26 Cone
225-19744-09 500 µl 57 26 Cone
225-19744-10 1 mL 57 23 Cone
225-19744-11 2.5 mL
For Headspace
65 23 Side Hole Dome

All syringes have fixed needles.

 
 
 
 
 