TORAST-H Vials

 
 
 
  • Low adsorbtion glass vial that is suitable for long-term starage
  • Minimized adsorbtion of bases, acids and neutrals
  • Superior quality control
 

TORAST-H Glass Technology eliminates the risk of adsorption to the glass surface of the vials

Glass, the material of vials, contains metal oxides. Oxides of metals have a high ionizing tendency to be Si-O-M (metal silanolate), which may cause ionic adsorption with basic compounds in the sample. TORAST-H Glass Technology uses special processing to remove metals from the glass and suppress adsorption of basic compounds.

Superior Quality Control

  • Hydrolitic class 1, 5.1 expansion borosiliciate glass
  • Comes with quality certificates for lot management
  • Shape inspection of vials, septum and caps
  • Low adsorption performance testing for basic, acidic and neutral compounds
 

TORAST-H Kits, Vials 1.5 ml Screw Neck

Content: 100 pcs. / pack
Including vials, caps and septum

 
 
 
P/N 370-04300-02 370-04300-04 370-04300-01 370-04300-03
Volumen [ml] 1.5 1.5 1.5 1.5
Septum
silicone/PTFE
slit
silicone/PTFE
slit
silicone/PTFE
silicone/PTFE
Material, color glass, clear glass, amber glass, clear glass, amber
Neck screw neck, wide open screw neck, wide open screw neck, wide open screw neck, wide open
Head O.D. [mm] 9 9 9 9
Dimension [mm] 32.0 x 11.6 32.0 x 11.6 32.0 x 11.6 32.0 x 11.6
Marking label and filling lines label and filling lines label and filling lines label and filling lines
 
 
 
 
 
 
 
 

TORAST-H Kits, Vials Screw Neck with 0.15 ml Micro-Insert

Content: 100 pcs. / pack
Including vials, caps and septum

 
 
 
P/N 370-04301-02 370-04301-04 370-04301-01 370-04301-03
Volumen [ml] 0.15 0.15 0.15 0.15
Septum
silicone/PTFE
slit
silicone/PTFE
slit
silicone/PTFE silicone/PTFE
Material, color glass, clear glass, amber glass, clear glass, amber
Neck screw neck, wide open screw neck, wide open screw neck, wide open screw neck, wide open
Head O.D. [mm] 9 9 9 9
Bottom open open open open
Dimension [mm] 32.0 x 11.6 32.0 x 11.6 32.0 x 11.6 32.0 x 11.6
Marking label and filling lines label and filling lines label and filling lines label and filling lines
 

TORAST-H Bio Vial with 0.3 ml Micro-Insert

 
  • Prevents the adsorbtion of organic compounds
  • Reduces the adsorptive loss of the precious sample
  • Ideal for peptide and basic compounds analysis
 
  • Inert Polypropylene vials to prevent sample adsorbtion
  • TORAST-H Bio vials have a special coating which inhibits the adsorption of peptide and basic compounds to the vial
  • Design for convenient use and 32 x 11.6 mm standard dimension for compatibility on all instrument auto-samplers
  • Content: 100 pcs. / pack
 
 
 
P/N 370-04350-00
Volumen [ml] 0.3
Septum penetration cap
Material, color PP, clear
Bottom open
Dimension [mm] 32.0 x 11.6
 
 
 
 
 
 
 
 

TORAST-H 96-well Plates

  • Low adsorption polypropylne 96-well plate
  • Prevents the adsorption of organic compounds
  • Reduces the adsorptive loss of precious sample
  • Ideal for analysis of peptides and basic compounds
 
  • Storage: avoid sunlight and store at room temperature
  • Non-sterile
 
 
P/N 370-04100-01 370-04020-01
Description 500 µl, round shallow well, U-bottom mat for round wells plate
Material, color PP, clear silicone, clear
Content 10 pcs. per pack 50 pcs. per pack
 
 
 
 
 
 

Additional Accessories

Racks and Boxes

Racks and boxes for 1.5 ml vials

Top of This Page