UV-2600i, UV-2700i

The compact UV-2600i/2700i is a universal, research-grade spectrophotometer that can be used in a wide range of fields, and easily expanded to suit the measurement objective. By using the optional integrating sphere, the measurement wavelength range of the UV-2600 can be extended to the near-infrared region of 1400 nm. The UV-2700 is capable of 8-Abs measurements, and optimal for measuring low transmittance samples.
LabSolutions UV-Vis is a next-generation Shimadzu UV control software pursuing efficiency of analysis. LabSolutions UV-Vis software with easy-to-use is included as standard.
- Perfect for a Wide Variety of User Applications
Spectral evaluation functionality enables unique pass/fail judgment for quality control. During measurements, data can be automatically sent to Excel in real time for using macros to automatically obtain desired values. - Measures Slight Differences in Absorbance
Near-infrared light can be measured.
Ultra-low stray light enables measurements down to absorbance values of 8 Abs. - Enables Compliance with ER/ES Regulations and Stronger Data Management.
Configurable as system for preventing data tampering.
Efficiently prevents data tampering from entire series of analytical process steps.
Features
Extensive Selection of Application Programs for a Wide Variety of User Applications
The functionality of the UV-2700i / 2600i can be freely expanded to suit the measurement objective. By accommodating a wealth of...
Measures Slight Differences in Absorbance
Double monochromator UV-2700i
quipped with a double monochromator that achieves ultra-low stray light levels, the UV-2700i is optimal for...
Enables Compliance with ER/ES Regulations and Stronger Data Management
The new spectrophotometer with the LabSolutions UV-Vis software which achieves labor-saving measurement provide a more convenient analytical environment.
Brochure download
Download the latest brochure.
Applications
Electricity, Electronics, and Optics
Band Gap Measurements for Compound Semiconductors
The diffuse reflection spectra for two types of compound semiconductors...
Window Glass Transmission Measurements
Two types of window glass were measured utilizing the ISR-2600Plus integrating...
Thickness Measurements of Cling Films
Undulating interference waveforms sometimes occur if light is passed...
Total Transmittance Spectrum of CNF
An ISR-2600Plus integrating sphere was used to measure the total transmittance spectrum of...
DNA and Protein Measurements
The red and blue lines are the absorption spectra for dsDNA and...
Vitamin Measurements
This shows the absorption spectra for riboflavin (vitamin B2). The sample concentrations are...