| Sample |
Analytical form and analytical condition |
Accessory |
|---|
| Solids |
Smooth surface samples (Metal, mirror, film, etc.) |
Transmittance Measurement |
Less than 3 mm thick |
Standard compartments+Film Holder |
|---|
| More than 3 mm thick |
Integrating Sphere Attachment (ISR-240A/2200/2600/3100) * |
| Large Integrating Sphere Attachment |
150øIntegrating Sphere Attachment (LISR-3100) <UV-3600 only> |
| Large sample size |
Multipurpose Large-Sample Compartment (MPC-2200/2600/3100) * or SolidSpec-3700 |
| Reflectance Measurement |
Relative Specular Reflectance Measurement |
Normal measurement |
Specular Reflectance Attachment (5゚ incident angle) |
| Large sample size |
SolidSpec-3700 + Large specular reflectance attachment (5゚ incident angle) |
| Absolute Specular Reflectance Measurement |
5゚ incident angle measurement |
Absolute Specular Reflectance Attachment (ASR-3105) * <only MPC-2200/3100+BIS-3100/3700> |
| 12/30/45゚ incident angle measurement |
Absolute Specular Reflectance Attachment (ASR-3112/3130/3145) * <Requires MPC-2200/3100+BIS-3100/3700+Polarizer Assy> |
| Tilting incident measurement |
Tilting incident Absolute Specular Reflectance Attachment (Special Order) * +Requires Polarizer Assy and Multipurpose Large-Sample Compartment (MPC-2200/3100) |
| Relative Diffuse Reflectance Measurement |
Normal measurement |
Integrating Sphere Attachment (ISR-240A/2200/2600/3100) * |
| Large Integrating Sphere Attachment |
150ØIntegrating Sphere Attachment (LISR-3100) <UV-3600 only> |
| Large sample size |
Multipurpose Large-Sample Compartment (MPC-2200//2600/3100) * or SolidSpec-3700 |
| Rough surface sample (Paper, plastic, etc) |
Transmittance Measurement |
Normal measurement |
Integrating Sphere Attachment (ISR-240A/2200/2600/3100) * |
| Large Integrating Sphere Attachment |
150ØIntegrating Sphere Attachment (LISR-3100) <UV-3600 only> |
| Large sample size |
Multipurpose Large-Sample Compartment (MPC-2200/2600/3100) * or SolidSpec-3700 |
| Reflectance Measurement |
Relative Diffuse Reflectance Measurement |
Normal measurement |
Integrating Sphere Attachment (ISR-240A/2200/2600/3100) * |
| Large Integrating Sphere Attachment |
150ØIntegrating Sphere Attachment (LISR-3100) <UV-3600 only> |
| Large sample size |
Multipurpose Large-Sample Compartment (MPC-2200/3100/2600) * or SolidSpec-3700 |
| Absolute Diffuse Reflectance Measurement |
Please consult with your rep. |
| Large sample size |
Multipurpose Large-Sample Compartment (MPC-2200/2600/3100) * or SolidSpec-3700 |