TIAFT-2023

The 60th meeting of The International Association of Forensic Toxicologists
August 27-31, 2023
Rome, Italy
https://www.tiaft2023.org
Meet Shimadzu at TIAFT
The 60th Annual Meeting of The International Association of Forensic Toxicologists (TIAFT) will take place between 27th and 31st August 2023 in Rome (Italy). Join Shimadzu for an exciting meeting focussing on NPS!
We kindly invite you to visit our booth to discover all the solutions (GCMS, LC-MS/MS, HRMS including automation and PESI ion source) available from Shimadzu to develop your services.
Shimadzu Journal Vol. 10, Issue 2 - Jul 2023

(1) Dr. Jose Luiz Costa (Campinas Poison Control Center, University of Campinas: Brazil)
The concept of green toxicological analysis (GAT) and new psychoactive substances in Brazil.
(2) Dr. Michelle Peace (Virginia Commonwealth University: U.S.A.)
The broad implications of vaping on public safety issues and developing methods for analyzing new THC isomers and derivatives.
Scientific Workshop: Monday 28th August | 12h20 - 13h00
"Enhancing automation & reporting confidence | innovative approached in toxicology.”
The CLAM-2040 automation module, the third of its generation since initial launch, has paved the way for the use of LCMS in clinical research and routine analysis since 2015.
By enabling easier implementation of the mass spectrometry coupled with liquid chromatography in laboratories, the CLAM module contributes to the democratization of the use of mass spectrometry in the clinical environment.
The new version, CLAM-2040, opens new doors in LCMS automation with the ability to connect LCMS-TQs and LCMS-QTOFs. Automated sample preparation prior to injection reduces time-consuming workload for lab technicians and improves sample-to-sample repeatability. Additional features such as the LIS connection and the optional LAS connection greatly expand the possibilities in the laboratory.
During this workshop, we will also discuss the use of an ambient ion source named Probe Electrospray (PESI) coupled with MS/MS to rapidly screen samples using isotope dilution approaches either with TQ Mass Spectrometers or HRMS QTOF systems, with applications for the measurement of drugs of abuse and benzodiazepines. Such a system, with limited sample preparation, is likely to simplify the implementation of mass spectrometry for its selectivity and accuracy as a replacement for immunoassays for rapid screening or measurement in an emergency context.
| Monday, August 28th | 12.20 – 13.00 “Enhancing automation & reporting confidence | innovative approached in toxicology” |
|---|---|
| 12h20 – 12h30 |
Automated workflows for LCMS (TQ/HRMS) Daisuke Kawakami, Shimadzu Europa GmbH
|
| 12h30 – 13h00 |
Innovative approaches for Toxicology studies using Mass Spectrometry Franck Saint Marcoux, CHU Limoges
|
Oral presentations
Wednesday, August 30th | O56
1] Study of the metabolism and possible drug-drug interactions of the novel cathinone derivative 3-MMC combining three in vitro approaches.
Zarrouk Eliès1*, Griffeuille Pauline1, El Balkhi Souleiman1, Saint-Marcoux Franck1, 2
1 Unit of biological and forensic toxicology, Limoges University Hospital, Limoges, France
2 Department of Toxicology, Faculty of Pharmacy, Limoges, France
Poster presentations
Monday, August 28th | P22
1] Less than 3 min for Detection and quantification of 18 benzodiazepines and designer benzodiazepines using Probe ElectroSpray Ionization Tandem Mass Spectrometry (PESI-MS/MS).
Pauline GRIFFEUILLE1*, Souleiman El BALKHI1, Pierre MARQUET1,2, Sylvain DULAURENT1, Franck SAINT-MARCOUX1,3
1 Department of pharmacology and toxicology, Limoges University Hospital, France
2 Pharmacology & Transplantation, UMR1248, INSERM, University of Limoges, France
3 Department of Toxicology, Faculty of Pharmacy, Limoges
lab4you Student Program
Need free lab space for your research? Then lab4you is for YOU! We are now again looking to support young, enthusiastic scientists with an interesting topic of research, by offering instrument time on the entire range of our state-of-the-art analytical equipment in the Shimadzu Laboratory World in Duisburg, Germany.

Product Lineup
Please contact us during the conference to get more information for the following instruments and solutions:













