UP223X

X Series with Internal Calibration Weights

Capacity

220g

Minimum display

0.001g

External Calibration Weight Range for Span Calibration

100 to 220g

Repeatability
(at Weighing Capacity)

≦0.001g

Linearity

± 0.002g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 3.4 kg

*1 Indicated response time values are typical.

Read more
Show Less

UP423X

X Series with Internal Calibration Weights

Capacity

420g

Minimum display

0.001g

External Calibration Weight Range for Span Calibration

100 to 420g

Repeatability
(at Weighing Capacity)

≦0.001g

Linearity

± 0.002g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 3.4 kg

Read more
Show Less

UP623X

X Series with Internal Calibration Weights

Capacity

620g

Minimum display

0.001g

External Calibration Weight Range for Span Calibration

100 to 620g

Repeatability
(at Weighing Capacity)

≦0.001g

Linearity

± 0.002g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 3.4 kg

Read more
Show Less

UP823X

X Series with Internal Calibration Weights

Capacity

820g

Minimum display

0.001g

External Calibration Weight Range for Span Calibration

400 to 820g

Repeatability
(at Weighing Capacity)

≦0.001g

Linearity

± 0.003g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 3.4 kg

Read more
Show Less

UP1023X

X Series with Internal Calibration Weights

Capacity

1020g

Minimum display

0.001g

External Calibration Weight Range for Span Calibration

500 to 1020g

Repeatability
(at Weighing Capacity)

≦0.001g

Linearity

± 0.003g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 3.4 kg

Read more
Show Less

UP2202X

X Series with Internal Calibration Weights

Capacity

2200g

Minimum display

0.01g

External Calibration Weight Range for Span Calibration

1000 to 2200g

Repeatability
(at Weighing Capacity)

≦0.01g

Linearity

± 0.02g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 176 x 189 mm

Weight

Approx. 4.6 kg

Read more
Show Less

UP4202X

X Series with Internal Calibration Weights

Capacity

4200g

Minimum display

0.01g

External Calibration Weight Range for Span Calibration

1000 to 4200g

Repeatability
(at Weighing Capacity)

≦0.01g

Linearity

± 0.02g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 176 x 189 mm

Weight

Approx. 4.6 kg

Read more
Show Less

UP6202X

X Series with Internal Calibration Weights

Capacity

6200g

Minimum display

0.01g

External Calibration Weight Range for Span Calibration

1000 to 6200g

Repeatability
(at Weighing Capacity)

≦0.01g

Linearity

± 0.02g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 176 x 189 mm

Weight

Approx. 4.6 kg

Read more
Show Less

UP422X

X Series with Internal Calibration Weights

Capacity

420g

Minimum display

0.01g

External Calibration Weight Range for Span Calibration

100 to 420g

Repeatability
(at Weighing Capacity)

≦0.008g

Linearity

± 0.01g

Response Time*1

Approx. 0.6 to 1.0 sec

Sensitivity Stability Against Temperature Range

± 5 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 3.4 kg

Read more
Show Less

UP822X

X Series with Internal Calibration Weights

Capacity

820g

Minimum display

0.01g

External Calibration Weight Range for Span Calibration

100 to 820g

Repeatability
(at Weighing Capacity)

≦0.008g

Linearity

± 0.01g

Response Time*1

Approx. 0.6 to 1.0 sec

Sensitivity Stability Against Temperature Range

± 5 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 3.4 kg

Read more
Show Less

UP4201X

X Series with Internal Calibration Weights

Capacity

4200g

Minimum display

0.1g

External Calibration Weight Range for Span Calibration

1000 to 4200g

Repeatability
(at Weighing Capacity)

≦0.08g

Linearity

± 0.1g

Response Time*1

Approx. 0.6 to 1.0 sec

Sensitivity Stability Against Temperature Range

± 5 ppm/°C (10 to 30°C)

Pan Size

Approx. 176 x 189 mm

Weight

Approx. 4.6 kg

Read more
Show Less

UP8201X

X Series with Internal Calibration Weights

Capacity

8200g

Minimum display

0.1g

External Calibration Weight Range for Span Calibration

1000 to 8200g

Repeatability
(at Weighing Capacity)

≦0.08g

Linearity

± 0.1g

Response Time*1

Approx. 0.6 to 1.0 sec

Sensitivity Stability Against Temperature Range

± 5 ppm/°C (10 to 30°C)

Pan Size

Approx. 176 x 189 mm

Weight

Approx. 4.6 kg

Read more
Show Less

UP223Y

Y Series without Internal Calibration Weights

Capacity

220g

Minimum display

0.001g

External Calibration Weight Range for Span Calibration

100 to 220g

Repeatability
(at Weighing Capacity)

≦0.001g

Linearity

± 0.002g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 2.7 kg

Read more
Show Less

UP423Y

Y Series without Internal Calibration Weights

Capacity

420g

Minimum display

0.001g

External Calibration Weight Range for Span Calibration

100 to 420g

Repeatability
(at Weighing Capacity)

≦0.001g

Linearity

± 0.002g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 2.7 kg

Read more
Show Less

UP623Y

Y Series without Internal Calibration Weights

Capacity

620g

Minimum display

0.001g

External Calibration Weight Range for Span Calibration

100 to 620g

Repeatability
(at Weighing Capacity)

≦0.001g

Linearity

± 0.002g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 2.7 kg

Read more
Show Less

UP823Y

Y Series without Internal Calibration Weights

Capacity

820g

Minimum display

0.001g

External Calibration Weight Range for Span Calibration

400 to 820g

Repeatability
(at Weighing Capacity)

≦0.001g

Linearity

± 0.003g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 2.7 kg

Read more
Show Less

UP1023Y

Y Series without Internal Calibration Weights

Capacity

1020g

Minimum display

0.001g

External Calibration Weight Range for Span Calibration

500 to 1020g

Repeatability
(at Weighing Capacity)

≦0.001g

Linearity

± 0.003g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 2.7 kg

Read more
Show Less

UP2202Y

Y Series without Internal Calibration Weights

Capacity

2200g

Minimum display

0.01g

External Calibration Weight Range for Span Calibration

1000 to 2200g

Repeatability
(at Weighing Capacity)

≦0.01g

Linearity

± 0.02g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 176 x 189 mm

Weight

Approx. 2.9 kg

Read more
Show Less

UP4202Y

Y Series without Internal Calibration Weights

Capacity

4200g

Minimum display

0.01g

External Calibration Weight Range for Span Calibration

1000 to 4200g

Repeatability
(at Weighing Capacity)

≦0.01g

Linearity

± 0.02g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 176 x 189 mm

Weight

Approx. 2.9 kg

Read more
Show Less

UP6202Y

Y Series without Internal Calibration Weights

Capacity

6200g

Minimum display

0.01g

External Calibration Weight Range for Span Calibration

1000 to 6200g

Repeatability
(at Weighing Capacity)

≦0.01g

Linearity

± 0.02g

Response Time*1

Approx. 1 sec.

Sensitivity Stability Against Temperature Range

± 3 ppm/°C (10 to 30°C)

Pan Size

Approx. 176 x 189 mm

Weight

Approx. 2.9 kg

Read more
Show Less

UP422Y

Y Series without Internal Calibration Weights

Capacity

420g

Minimum display

0.01g

External Calibration Weight Range for Span Calibration

100 to 420g

Repeatability
(at Weighing Capacity)

≦0.008g

Linearity

± 0.01g

Response Time*1

Approx. 0.6 to 1.0 sec

Sensitivity Stability Against Temperature Range

± 5 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 2.7 kg

Read more
Show Less

UP822Y

Y Series without Internal Calibration Weights

Capacity

820g

Minimum display

0.01g

External Calibration Weight Range for Span Calibration

100 to 820g

Repeatability
(at Weighing Capacity)

≦0.008g

Linearity

± 0.01g

Response Time*1

Approx. 0.6 to 1.0 sec

Sensitivity Stability Against Temperature Range

± 5 ppm/°C (10 to 30°C)

Pan Size

Approx. 113 x 110 mm

Weight

Approx. 2.7 kg

Read more
Show Less

UP4201Y

Y Series without Internal Calibration Weights

Capacity

4200g

Minimum display

0.1g

External Calibration Weight Range for Span Calibration

1000 to 4200g

Repeatability
(at Weighing Capacity)

≦0.08g

Linearity

± 0.1g

Response Time*1

Approx. 0.6 to 1.0 sec

Sensitivity Stability Against Temperature Range

± 5 ppm/°C (10 to 30°C)

Pan Size

Approx. 176 x 189 mm

Weight

Approx. 2.9 kg

Read more
Show Less

UP8201Y

Y Series without Internal Calibration Weights

Capacity

8200g

Minimum display

0.1g

External Calibration Weight Range for Span Calibration

1000 to 8200g

Repeatability
(at Weighing Capacity)

≦0.08g

Linearity

± 0.1g

Response Time*1

Approx. 0.6 to 1.0 sec

Sensitivity Stability Against Temperature Range

± 5 ppm/°C (10 to 30°C)

Pan Size

Approx. 176 x 189 mm

Weight

Approx. 2.9 kg

Read more
Show Less
{"title":"Specification Sheet Downloads","description":"Download the latest specification sheets.","source":"product","key":3532,"max":30,"filter_types":["spec_sheet"],"link_title":"View other Downloads","link_url":""} {"title":"Downloads","description":"Download the latest brochure.","source":"product","key":3532,"max":30,"filter_types":["brochures"],"link_title":"View other Downloads","link_url":"","pdf_links":[]}