LC Detector Lamp
Name P/N Qty Remarks Applicable models
Tungsten (W) Lamp for SPD 1 Guaranteed service life is 2000 hours or one year after the phrchase date, whichever is shorter. M40
Tungsten (W) Lamp for SPD 1 Guaranteed service life is 1200 hours or one year after the phrchase date, whichever is shorter. 40V
Tungsten (W) Lamp for SPD 1 including W Lamp: 062-65012-04, socket, lead cable and jig Guaranteed service life is 2000 hours or one year after the purchase date. optional for 2040C 3D MT
optional for 2040C 3D
optional for 2030C 3D
Tungsten (W) Lamp for SPD 1 Guaranteed service life is 2000 hours or one year after the purchase date. Socket for W Lamp (P/N: 228-34671-41) is necessary when installing. optional for 2040C 3D MT
optional for 2040C 3D
optional for 2030C 3D
Tungsten (W) Lamp for SPD 1 Average service life is 2000 hours. Guaranteed service life is 1200 hours or one year after the purchase date. 20AV
10AV
10AVi
10AVVP
Tungsten (W) Lamp for SPD 1 Average service life is 2000 hours. Guaranteed service life is 1200 hours or one year after the purchase date. M20A
M10AVP
optional for 2040C 3D MT
optional for 2040C 3D
optional for 2030C 3D
optional for M10AV
optional for 7AV
optional for M6A
optional for 6A
Tungsten (W) Lamp for RID 1 The lamp should be replaced by a service engineer. 20A
10A
Tungsten (W) Lamp for RID 1 The lamp should be replaced by a service engineer. 6A
Xenon (Xe) Lamp for RF 1 UXL-155A. Guaranteed service life is 500 hours or one year after the purchase date (if purchased for a fee). Needs to be replaced before the operation time reaches 1000 hours. 10AXL
10AXL Super
Xenon (Xe) Lamp for RF 1 UXL-155, with a timer. Guaranteed service life is 500 hours or one year after the purchase date (if purchased for a fee). Needs to be replaced before the operation time reaches 1000 hours. 535
Deuterium (D2) Lamp for SPD 1 L14578-02
Guaranteed service life is 2000 hours or one year after the purchase date, whichever is shorter.
M40
Deuterium (D2) Lamp for SPD 1 L15050
Guaranteed service life is 2000 hours or one year after the purchase date.
40
40V
Deuterium (D2) Lamp for SPD 1 L12519 Guaranteed service life is 2000 hours or one year after the purchase date. 2040C MT
2040
2030
2030C
Deuterium (D2) Lamp for SPD 1 L12519-01 Guaranteed service life is 2000 hours or one year after the purchase date. 2040C 3D MT
2040C 3D
2030C 3D
optional for 2040C MT
optional for 2040C
optional for 2030
optional for 2030C
Deuterium (D2) Lamp for SPD 1 L12269 Guaranteed service life is 2000 hours or one year after the purchase date. M30A
Deuterium (D2) Lamp for SPD 1 L6585-02. Guaranteed service life is 2000 hours or one year after the purchase date. 20A
20A(UFLC)
20AV
10A
10Ai
10AVP
10AV
10AVi
10AVVP
10AVVP INERT
Deuterium (D2) Lamp for SPD 1 L6585. Guaranteed service life is 2000 hours or one year after the purchase date. M20A
M10AVP
optional for 20A
optional for 20A(UFLC)
optional for 20AV
optional for 10A
optional for 10Ai
optional for 10AVP
optional for 10AV
optional for 10AVi
optional for 10AVVP
optional for 10AVVP INERT
Deuterium (D2) Lamp for SPD 1 L8169. Guaranteed service life is 2000 hours or one year after the purchase date. 2010
Deuterium (D2) Lamp for SPD 1 L12315 *
Guaranteed service life is 2000 hours or one year after the purchase date.
optional for 2010
Deuterium (D2) Lamp for SPD 1 L5235, with HB socket. Guaranteed service life is 1000 hours or one year after the purchase date. M10A
M10AV
Deuterium (D2) Lamp for SPD 1 L6381.Guaranteed service life is 500 hours or one year after the purchase date. 7A
7AV
6A
6AV
Flow Cell
Name P/N Qty Remarks Applicable models
For Photodiode Array Detectors 1 Standard cell for SPD-M40
optical path length: 10 mm, volume: 12 μL,
with temperature control function
40
40V
For Photodiode Array Detectors 1 UHPLC cell (ultra high-separation, high-speed analysis)
optical path length: 10 mm, volume: 8μL,
with temperature control function
optional for 40
optional for 40V
For Photodiode Array Detectors 1 Semi micro cell
optical path length: 5 mm, volume: 2.5 μL,
with temperature control function
optional for 40
optional for 40V
For Photodiode Array Detectors 1 Cell for conventional analysis
optical path length: 10 mm, volume: 12 μL
It has the same internal capacity as the SPD-20A/20AV standard cell.
optional for 40
optional for 40V
For Photodiode Array Detectors 1 Inert cell
optical path length: 10 mm, volume: 12 μL,
with temperature control function
optional for 40
optional for 40V
For Photodiode Array Detectors 1 Preparative cell
optical path length: 0.5 mm (variable among 0.1, 0.2 0.5 mm), volume: 4 μL
optional for 40
optional for 40V
For Photodiode Array Detectors 1 Micro LC cell
optical path length: 3 mm, volume: 0.21 μL
optional for 40
optional for 40V
For Photodiode Array Detectors 1 High pressure resistance (pressure resistance: 40 MPa)
optical path length: 10 mm, volume: 12 μL
optional for 40
optional for 40V
For Photodiode Array Detectors 1 Standard cell for LC-2040, for high-sensitivity, high-speed analysis optical path length: 10 mm, volume: 8 μL, with temperature control function 2040C 3D MT
2040C 3D
optional for 2030C 3D
For Photodiode Array Detectors 1 Standard cell for LC-2030 optical path length: 10 mm, volume: 12 μL, with temperature control function 2030C 3D
optional for 2040C 3D MT
optional for 2040C 3D
For Photodiode Array Detectors 1 Semi-micro cell, for semi-micro analysis optical path length: 5 mm, volume: 2.5 μL, with temperature control function optional for 2040C 3D MT
optional for 2040C 3D
optional for 2030C 3D
For Photodiode Array Detectors 1 Standard cell for SPD-M30A (total-reflection capillary cell) optical path length: 10 mm, volume: 1 μL M30A
For Photodiode Array Detectors 1 High-sensitivity cell (total-reflection capillary cell) optical path length: 85 mm, volume: 8.5 μL optional for M30A
For Photodiode Array Detectors 1 Low-diffusion cell (total-reflection capillary cell) optical path length: 10 mm, volume: 1 μL optional for M30A
For Photodiode Array Detectors 1 Standard cell for SPD-M20A optical path length: 10 mm, volume: 10 μL, with temperature control function M20A
For Photodiode Array Detectors 1 Standard cell for SPD-M10A optical path length: 10 mm, volume: 10 μL M10A
M10AV
M10AVP
optional for M20A
For Photodiode Array Detectors 1 Semi-micro cell optical path length: 5 mm, volume: 2.5 μL, with temperature control function optional for M20A
For Photodiode Array Detectors 1 for high-sensitivity, high-speed analysis optical path length: 10 mm, volume: 8 μL, with temperature control function optional for M20A
For Photodiode Array Detectors 1 Semi-micro cell optical path length: 5 mm, volume: 2.5 μL, with temperature control function optional for M20A
optional for M10A
optional for M10AV
optional for M10AVP
For Photodiode Array Detectors 1 Micro cell optical path length: 3 mm, volume: 0.21 μL optional for M20A
optional for M10A
optional for M10AV
optional for M10AVP
For Photodiode Array Detectors 1 for inert analysis optical path length: 10 mm, volume: 18 μL optional for M20A
optional for M10A
optional for M10AV
optional for M10AVP
For Photodiode Array Detectors 1 Preparative cell optical path length: 0.5 mm (fixed), volume: 6.5 μL optional for M20A
optional for M10A
optional for M10AV
optional for M10AVP
For Photodiode Array Detectors 1 Preparative cell optical path length: 0.5 mm (variable among 0.1, 0.2, 0.5 mm), volume: 4 μL optional for M20A
optional for M10A
optional for M10AV
optional for M10AVP
For Photodiode Array Detectors 1 Preparative cell optical path length: 0.2 mm (variable among 0.1, 0.2, 0.5 mm), volume: 1.6 μL optional for M20A
optional for M10A
optional for M10AV
optional for M10AVP
For Photodiode Array Detectors 1 Preparative cell optical path length: 0.1 mm (variable among 0.1, 0.2, 0.5 mm), volume: 0.8 μL optional for M20A
optional for M10A
optional for M10AV
optional for M10AVP
For RF Detectors 1 Standard cell for RF-20Axs, with temperature control function 20Axs
For RF Detectors 1 Standard cell for RF-20A 20A
For RF Detectors 1 Semi-micro cell (when attached on the 20Axs, the temperature control function is supported.) optional for 20Axs
optional for 20A
For RF Detectors 1 Inert cell (materials of the part contacting solutions: Quartz, PTFE, and PEEK) optional for 20Axs
optional for 20A
For RF Detectors 1 Standard cell for RF-10AXL 10AXL
optional for 10A
optional for 550
For RF Detectors 1 Standard cell for RF-10AXL Super 10AXL Super
For RF Detectors 1 Cell for inert (PEEK) optional for 10AXL
optional for 10A
optional for 550
For RF Detectors 1 Cell for inert semi-micro (PEEK) optional for 10AXL
optional for 10A
optional for 550
For RF Detectors 1 Cell main unit (for standard cells and inert cells) optional for 10AXL
optional for 10AXL Super
optional for 10A
optional for 550
For RF Detectors 1 Cell main unit (for semi-micro cells) optional for 10AXL
optional for 10A
optional for 550
For UV Detectors 1 Standard cell for SPD-40/40V
optical path length: 10 mm, volume: 12 μL
temperature control function
40
40V
For UV Detectors 1 UHPLC cell (ultra high-separation, high-speed analysis)
optical path length: 10 mm, volume: 8μL
temperature control function
optional for 40
optional for 40V
For UV Detectors 1 Semi micro cell
optical path length: 5 mm, volume: 2.5 μL
temperature control function
optional for 40
optional for 40V
For UV Detectors 1 Cell for conventional analysis
optical path length: 10 mm, volume: 12 μL
It has the same internal capacity as the SPD-20A/20AV standard cell.
optional for 40
optional for 40V
For UV Detectors 1 Inert cell
optical path length: 10 mm, volume: 12 μL
temperature control function
optional for 40
optional for 40V
For UV Detectors 1 Preparative cell, optical path length: 0.5 mm(variable among 0.1, 0.2, 0.5 mm), volume: 4 μL optional for 40
optional for 40V
For UV Detectors 1 Micro cell
optical path length: 3 mm, volume: 0.21 μL
optional for 40
optional for 40V
For UV Detectors 1 Cell for high pressure resistance (pressure resistance : 40MPa)
optical path length: 10 mm, volume: 12 μL
optional for 40
optional for 40V
For UV Detectors 1 Standard cell for LC-2040, for high-sensitivity, high-speed analysis optical path length: 10 mm, volume: 8 μL, with temperature control function 2040C MT
2040C
optional for 2030
optional for 2030C
For UV Detectors 1 Standard cell for LC-2030, for high-sensitivity, high-speed analysis optical path length: 10 mm, volume: 12 μL, with temperature control function 2030
2030C
optional for 2040C MT
optional for 2040C
For UV Detectors 1 Semi-micro cell, for semi-micro analysis optical path length: 5 mm, volume: 2.5 μL, with temperature control function optional for 2040C MT
optional for 2040C
optional for 2030
optional for 2030C
For UV Detectors 1 Standard cell for LC-2010 optical path length: 10 mm, volume: 8 μL, with temperature control function 2010
2010HT
For UV Detectors 1 Semi-micro cell optical path length: 5 mm, volume: 2.4 μL, with temperature control function optional for 2010
optional for 2010HT
For UV Detectors 1 Standard cell for SPD-20A optical path length: 10 mm, volume: 12 μL, with temperature control function 20A
20AV
For UV Detectors 1 Standard cell for SPD-10A optical path length: 10 mm, volume: 8 μL 10A
10AV
10AVP
10AVVP
optional for 20A
optional for 20AV
For UV Detectors 1 Semi-micro cell optical path length: 5 mm, volume: 2.5 μL, with temperature control function optional for 20A
optional for 20AV
For UV Detectors 1 For high-sensitivity, high-speed analysis optical path length: 10 mm, volume: 8 μL, with temperature control function; optical path length: 10 mm optional for 20A
optional for 20AV
For UV Detectors 1 Semi-micro cell optical path length: 5 mm, volume: 2.5 μL optional for 20AV
optional for 10A
optional for 10AV
optional for 10AVP
optional for 10AVVP
optional for 20A
For UV Detectors 1 Micro cell (with printed board PB-1) optical path length: 3 mm, volume: 0.21 μL optional for 20A
optional for 20AV
optional for 10A
optional for 10AV
optional for 10AVP
optional for 10AVVP
For UV Detectors 1 Cell for Fast LC optical path length: 3 mm, volume: 2.4 μL optional for 20A
optional for 20AV
optional for 10A
optional for 10AV
optional for 10AVP
optional for 10AVVP
For UV Detectors 1 Cell for high pressure (pressure resistance: 39.2 Mpa) optical path length: 6 mm, volume: 3 μL optional for 20A
optional for 20AV
optional for 10A
optional for 10AV
optional for 10AVP
optional for 10AVVP
For UV Detectors 1 Preparative cell optical path length: 0.5 mm (fixed), volume: 6.5 μL optional for 20A
optional for 20AV
optional for 10A
optional for 10AV
optional for 10AVP
optional for 10AVVP
For UV Detectors 1 Preparative cell optical path length: 0.5 mm (fixed), volume: 6.5 μL optional for 20A
optional for 20AV
optional for 10A
optional for 10AV
optional for 10AVP
optional for 10AVVP
For UV Detectors 1 Preparative cell optical path length: 0.2 mm (variable among 0.1, 0.2, 0.5 mm), volume: 1.6 μL optional for 20A
optional for 20AV
optional for 10A
optional for 10AV
optional for 10AVP
optional for 10AVVP
For UV Detectors 1 Preparative cell optical path length: 0.2 mm (variable among 0.1, 0.2, 0.5 mm), volume: 1.6 μL optional for 20A
optional for 20AV
optional for 10A
optional for 10AV
optional for 10AVP
optional for 10AVVP
For UV Detectors 1 Standard cell for SPD-10Ai (connected flow path: PEEK, quartz), for inert analysis optical path length: 10 mm, volume: 16 μL 10Ai
10AVi
10AVP INERT
optional for 20A
optional for 20AV
optional for 10A
optional for 10AV
optional for 10AVP
optional for 10AVVP
For UV Detectors 1 Preparative cell optical path length: 0.5 mm (fixed), volume: 6.5 μL optional for 6A
optional for 6AV
For UV Detectors 1 Preparative cell optical path length: 0.5 mm (variable among 0.1, 0.2, 0.5 mm), volume: 4 μL optional for 6A
optional for 6AV
For UV Detectors 1 Preparative cell optical path length: 0.2 mm (variable among 0.1, 0.2, 0.5 mm), volume: 1.6 μL optional for 6A
optional for 6AV

Supplementary keywords: UV detector, UV-VIS, spectrophotometer, fluorescence, refractometer, refractive index, spectrofluorometric, PDA, photodiode array, 3D, inert, xenon lamp, deuterium, tungsten, halogen, SPD-M30A, SPD-M20A, SPD-20A, SPD-10A, SPD-7A, SPD-6A, SPD-M10A, RID-10A, RID-6A, RF-535, RF-550, RF-10A, LC-2010, LC-2030, LC-2040, Nexera, Prominence, SPD-40, SPD-40V, UV detector, RF-20A,