ALTRACE
Energy Dispersive X-ray Fluorescence Spectrometer
Detecting heavy metal with confidence
A combination of optical system design and Shimadzu's proprietary high-speed signal processing technology allows ALTRACE to reach new heights in terms of sensitivity.
Direct measurement from 0.1 ppm to several percent without sample preparation. Detect down to 0.1 ppm for Cd and Pb with a high-sensitivity 100 W source and get results within minutes. Process up to 48 samples per run, with racks that can be exchanged during measurement for continuous operation. Low running costs and easy handling with no specialist required, plus seamless integration with LabSolutions EDX, streamline routine analysis.
-
Discover the new Shimadzu ALTRACE
- Ultra-trace Detection (0.1 ppm Cd, Pb)
Measures heavy metals directly, from trace levels to several percent - High Throughput (48 samples per run)
Sample racks can be exchanged during measurement for continuous operation - Fast, Cimple and Cost-Efficient
Non-destructive results in minutes, with minimal running costs and no complex prep
- Ultra-trace Detection (0.1 ppm Cd, Pb)
-

Trace metal in minutes — talk to our team!
Download: Full Product Brochure — ALTRACE
Explore the ALTRACE brochure to see how Shimadzu’s benchtop ED‑XRF sets a new benchmark in routine elemental analysis. Download the brochure for specifications, compliance features, and software integration.
ALTRACE: Explore by Topic
Unparalleled Sensitivity that Goes Beyond Typical Measurement Needs
With Shimadzu’s combination of optical system design and proprietary high-speed signal processing, ALTRACE reaches the highest detection sensitivity compared to Shimadzu’s general-purpose systems (EDX-7200).
-
The combination of optical system that optimally arranges high-power X-ray tube and high-sensitivity detector, and high-speed signal processing has achieved high detection efficiency.
In the analysis of aqueous solution samples, the detection limit for all elements have been improved compared to the conventional equipment (EDX-7200).
It can be used effectively for the analysis of low-concentration samples and the automatic analysis of multiple samples requiring shorter measurement time.
Comparison of detection limit between conventional
equipment (EDX-7200) and ALTRACE

Implements batch element analysis across a wide range from the sub ppm level to the % level

Automatic Filter Exchange Improves Sensitivity
Background removal is facilitated by a primary X-ray filter, thereby improving S/N ratio. For trace-level analysis, where background is not negligible, filters are particularly advantageous.
ALTRACE is equipped with 6 primary filters (8 types, including open and attenuator), which can be exchanged autonomously by the software.-
Effective Energy (keV) Example of Applicable Elements Filter #1 14 to 38 Mo,Rh,Pd,Ag,Cd,Sn,Sb Filter #2 2 to 4 S,Cl Filter #3 5 to 10 r,Mn,Fe,Co,Ni Filter #4 9 to 10 Hg Filter #5 9 to 14 As,Br,Zr,Hg,Pb,Bi Filter #6 4 to 5 Ti,V

Escape from Complicated Pretreatment
When performing quantitative analysis by specifying elements, once a calibration curve is created, there is no need to recreate the calibration curve for each measurement. In addition, ALTRACE is suitable for simple screening analysis, since qualitative and quantitative analysis using the fundamental-parameter (FP) method can be performed without specifying elements Liquids and powders can be directly measured by simply placing them as is in the sample cell. EDX is a non-destructive technique; therefore, the same sample can be measured for both simple screening and precision analysis. To date, previous EDX systems could not measure concentrations on the order of 0.1 ppm. With ALTRACE, this level is now detectable. It is now possible to obtain sub-ppm level detection, without the need for chemical pretreatment.

Solids, Powders and Liquids Can Be Measured As Is
With ALTRACE, samples are placed into a dedicated sample cell. The sample is supported by a transparent X-ray film that is suitable for the sample.
-
Powdered Samples and Pellet Samples
Powder and pellet samples are placed in the sample cell and supported with polypropylene film.
-
Liquid Samples (Water Soluble and Oleaginous)
Aqueous solutions are poured into the sample cell and supported on a polypropylene film. Other liquids, such as organic solvents, can be measured by using an appropriate film.
High Throughput and Efficiency
Automatic Consecutive Analyses of Up to 48 Samples

710mm wide main body is equipped with a multi-sample changer. The tray drawer system allows for safe sample replacement without having to access the inside of the instrument.
Analysis can be Paused and Reassigned, Increasing Flexibility

During analysis, ALTRACE can be paused, and new samples can be added and the analysis schedule adjusted accordingly. As such, there is no need to wait for analysis to be completed to start sample preparation.
Application Highlights
Discover application notes and technical guides that help you set up, validate, and optimize your ALTRACE ED‑XRF workflows.
-
Application Note
Analysis of Hazardous Elements in Polluted Soil: Soil Contamination Countermeasures Act, JIS K 0470
-
Application Note
Screening Analysis for Hazardous Heavy Metals in Foods and Food Additives using Energy Dispersive X-ray Fluorescence Spectrometer
-
Application Note
Screening Analysis for Hazardous Heavy Metals in Foods and Food Additives
Explore more solutions for your analysis
Explore related products to find the right technique and capacity for your samples and regulations.
-
ICPE-9800 Series of simultaneous ICP atomic emission spectrometers are next-generation systems that offer the superior accuracy necessary to simultaneously and quickly analyze multiple elements regardless of their concentration levels.
-
Without the need for any special options, it reduces measurement time, contributing to the optimization of your workflow efficiency. Moreover, the software comes with various functions, options, and maintenance information that minimize operator intervention, revolutionizing the way you work.
-
The EDX-7200 is a flagship model of the EDX series in pursuit of high sensitivity, high speed and high precision. This model supports new regulations and directives for consumer and environmental compliance, such as RoHS/ELV, REACH, and TSCA with full exclusive screening analysis kits.
-
The Shimadzu Atomic Absorption Spectrophotometer AA -7800 Series is versatile enough for a variety of analytical applications (Any Application), safe and easy to use even for beginners (Any User), and offers continuous analysis using autosamplers and remote data analysis via network connections to increase the flexibility of the analysis operator's work style (Any Location).
ALTRACE is a trademark of Shimadzu Corporation or its affiliated companies in Japan and/or other countries.
Intel and intel Core are trademarks of Intel Corporation or its subsidiaries.
Windows is either a registered trademark or a trademark of Microsoft Corporation in the United States and/or other countries.
.jpg)