GC-2060

The Nexis GC 2060 is Shimadzu’s new flagship GC platform – built to handle today’s routine and complex tasks and ready to adapt to tomorrow’s demands. Whether in chemical, GX or environmental labs: It combines high performance detectors, flexible configuration and smart automation to make GC work simpler, more reliable and more efficient, while supporting long term investment security and cost-conscious operation.

 

 

  • Discover the new Shimadzu Nexis GC-2060

    • Versatile by design
      One platform for a wide range of applications, from routine checks to demanding methods
    • Expandable and future ready
      Broad expandability, flexible carrier gas choice and a clear roadmap for future needs
    • Efficient in daily use
      High-performance detectors, Analytical Intelligence and Eco Idling to reduce effort and costs

     
  • Nexis GC-2060

Celebrating 70 Years of Gas Chromatography

GC 70 Year Anniversary Shimadzu


 

 

 

Download: Full Product Brochure — Nexis GC-2060

Nexis GC-2060

 

 

Explore the Nexis GC-2060 brochure to see how Shimadzu’s flagship GC platform streamlines routine checks and complex methods with versatile configurations, smart automation, and future-ready expandability. Download the brochure for detector options, efficiency-boosting features, and integration details.

 

 

Nexis GC-2060: Explore by Topic

 

 

 

 

Features

Innovations Crafted Through Generations

Built on 70 years of technological expertise, the Nexis GC-2060 is Shimadzu’s flagship GC and a new benchmark for the industry. It pairs proven reliability with ongoing innovation to boost throughput, reduce downtime, and provide laboratories with a trusted partner now and well into the future.



Broaden Analytical Capabilities:
Multi-Mode Injection Unit (MMI)

  • Nexis GC-2060
  • The new MMI supports split/splitless, programmable temperature vaporization, direct injection, large-volume injection, thermal desorption and extraction modes. This expanded range of injection modes provides greater application flexibility and streamlines operation for even the most challenging samples.


Detectors with Unmatched Sensitivity and Stability:
Next-Gen FID & TCD

  • Nexis GC-2060

     

  • A complete redesign of the FID and TCD results in industry-leading sensitivity and long-term stability. The Nexis GC-2060 can also be configured with ECD, FPD, FTD, BID, and other detectors, providing the flexibility to support a broad range of applications.



A GC Crafted to Expand with Your Needs

  • Nexis GC-2060
  • The Nexis GC-2060 supports up to two injectors, three injection units and four detectors simultaneously. This flexibility allows one system to handle multiple applications with ease while saving valuable bench space and maximizing versatility.



Immediate Performance Right Out of the Box

  • Nexis GC-2060

     


  • Highly compatible with existing methods and consumables, the Nexis GC-2060 integrates seamlessly into your existing workflow, allowing your lab to begin using the system immediately under familiar conditions with minimal revalidation.

 

 


Benchmark in Analytical Efficiency

Multi-Mode Injection Units:
The Near Zero-Maintenance Downtime Injection Units

The Nexis GC-2060 MMI supports split/splitless, programmable temperature vaporization (PTV), direct, large-volume injection (LVI), and thermal desorption/extraction injections in a single module. This innovative design preserves data compatibility with the conventional split/splitless injection unit (SPL), allowing you to expand capabilities without revalidating existing methods.

High Performance with Minimal Downtime

  • Contaminated samples often mean frequent liner swaps. In addition, slow injection unit temperature changes can cost valuable time. Shimadzu’s proprietary injection unit insulation delivers excellent temperature stability plus rapid heating and cooling, cutting wait times and keeping your lab running efficiently.


    Comparison of Instrument Downtime by Maintenance

    Nexis GC-2060

     

  • Nexis GC-2060

    Chromatogram Comparison of FAME (Fatty Acid Methyl Esters)

 

  • Nexis GC-2060

    SPL (Heating)

  • Nexis GC-2060

    MMI (Heating)

  • Nexis GC-2060

    MMI (Cooling)

 

Flexible Injection Modes and Seamless Method Transfer

  • An intuitive software interface lets users switch instantly between split/splitless, PTV, large-volume injection, thermal desorption/extraction (TD/TE), and direct modes. A built-in universal mode streamlines method transfer from other brands or legacy instruments, minimizing revalidation and downtime.

  • Nexis GC-2060

     

 

Large-Volume Injection (LVI) Simplifies Complex Workflows

  • The LVI mode in the MMI concentrates samples in the injection unit, eliminating complex sample preparation steps. The bundled calculation tool speeds up method optimization, allowing users to reach the best conditions faster and more efficiently.

  • Nexis GC-2060

    Chromatogram Under Large-Volume Injection (C13, C14, C15, C16)

 


Revolutionizing Efficiency through Detector Precision
Industry-Leading Sensitivity, Linearity, and Stability

Next-Gen Flame Ionization Detector (FID)

  • The redesigned FID in the Nexis GC-2060 reaches a minimum detectable level of 1.0 pg C/s. In addition, it is the world’s first multi-mode FID (MMF)*1 equipped with Hy/Ox and Hy/Air modes, which allow flexible selection of detector gases, as well as Shimadzu’s proprietary Jetanizer and Polyarc modes.
    *1 Hy/Ox, Jetanizer, and Polyarc modes are optional

  • Nexis GC-2060

FID Polyarc Mode: Single Calibration for Diverse Organic Compounds

  •  Nexis GC-2060
  • Nexis GC-2060

    Relative Sensitivity Comparison Between FID and FID Polyarc Mode

  • The Polyarc delivers consistent universal FID response across diverse organic compounds by converting them to CH4 prior to FID detection. This enables a single calibration approach and reduces time spent preparing dedicated calibration standards.

  • Nexis GC-2060


    Number of standards required for calibration curve preparation

 

Next-Gen Thermal Conductivity Detector (TCD)

  • Nexis GC-2060
  • Nexis GC-2060

     

  • The redesigned TCD uses single-filament technology to dramatically reduce start-up time. With industry-leading sensitivity and excellent linearity, it stabilizes quickly and delivers accurate, repeatable results for a variety of gas and inorganic analyses.

  • Nexis GC-2060


    Comparison of TCD sensitivity stabilization time after startup

 


 

Smart Resource Management for Long-Term Savings
Eco Idling — The Next Standard for GC Standby

Eco Idling — The Next Standard for GC Standby

  • The Nexis GC-2060 is equipped with an “Automatic Eco-Operation” function that learns analytical patterns from operating history and performs optimal eco-friendly operation. The system delivers maximum performance during analysis and automatically switches to energy-saving (Eco Idling) mode during standby. In addition, the software displays the amount of gas and power savings, CO2 emissions reductions, and cost savings.

  • Nexis GC-2060

    Power consumption comparison

  • Fully Automatic Operation
    Once the initial settings are made, no manual action is required to switch to Eco Idling mode. Analysis can start directly from Eco Idling, and the system automatically returns to Eco Idling after completion.
     

    Nexis GC-2060
  • Energy-Saving Mode Without Compromising Analytical Performance
    The system delivers the same analytical performance as during a regular run. In addition, the transition from Eco Idling to analysis-ready status is completed in just a few minutes.

    Nexis GC-2060

     

 

Additional Cost-Saving Solutions

  • Gas Selector
    Automatically switch from helium to nitrogen or hydrogen when idle to significantly reduce helium use and lower running costs.
     

    Nexis GC-2060

     

  • Hydrogen Carrier Gas Ready
    Supports hydrogen carrier gas with a built-in hydrogen sensor for safe operation. Take advantage of hydrogen’s faster diffusion to shorten analysis times and increase throughput.
     

    Nexis GC-2060

     

 


 

Experience Effortless Control With an Intuitive Interface
Designed for Users of All Skill Levels


  • Nexis GC-2060

     

  • One-Touch Injection Unit Access

    Standard ClickTek lets you open and close the sample injection unit tool-free by hand, making liner replacement quick, simple and safe.
     

    Easy sTop Nexis GC-2060

    Press the MAINT. button and the GC automatically cools the injection unit, stops gas flow and enters a safe maintenance state. After maintenance, press the button again to restore normal standby — no complex procedures required.
     

    ECO Button

    Press the ECO button to enable Eco Idling mode, which automatically reduces gas flow and power. Press again to resume normal operation for tasks such as column conditioning. Simple to use, Eco Idling saves energy and lowers running costs.
     

    Tool-Free Column Installation

    ClickTek*2 connector — the same reliable connector adopted with the Nexis GC-2030 — lets users quickly install columns tool-free by hand. A tactile click confirms secure locking, speeding column setup and reducing installation errors.
    *2 Option

 

 

Automated GC Start and Stop

* Integrated with Eco Idling for seamless energy-saving operation

Nexis GC-2060 uses optimized sequences to automatically control gas flows and temperature for safe, unattended startup and shutdown. When idle, power and gas consumption are reduced, delivering greater cost savings than when using ECO Idling alone while also protecting the instrument.

Nexis GC-2060

 

 

 

Column Protection Nexis GC-2060

 

  • Precise control of the oven cooling rate prevents thermal shock to GC columns, extending column lifetime and ensuring stable data quality. When connected to the optional Gas Selector and a standby gas cylinder, the system auto-switches when the main supply of carrier gas runs low, avoiding gas outages that can damage columns.

  • Nexis GC-2060

    Column Oven Temperature During Cooling

 

Automated Column Conditioning — Clean Pilot  Nexis GC-2060

* Integrated with Eco Idling for seamless energy-saving operation

  • At GC startup or the beginning of batch runs, baseline drift can occur. Clean Pilot rapidly and automatically conditions the column, reducing operator workload and ensuring more stable, reliable results.

  • Nexis GC-2060

     

 


Access Information from Anywhere

On-Demand Maintenance Support and Troubleshooting

Access step-by-step maintenance instructions and troubleshooting guides instantly from the system. Scan the QR code displayed on the GC panel to view procedure videos on your portable device or view the same content via Remote Display*3 on the PC connected to the GC. Fast and clear support is readily available even when network access is limited.
*3 An application for Windows® devices. Can be connected simultaneously with workstations such as LabSolutions.

Nexis GC-2060

 

Intuitive Software Interface


  • ソフトウェアインターフェース
  • The graphical user interface mirrors the instrument’s flow path and layout, allowing gas flow and temperature settings to be visible at a glance. Clear visuals and familiar controls let users set parameters intuitively, avoiding confusion from vendor-specific terminology and operational differences. This simplifies the transition when migrating from legacy Shimadzu GC or third-party GC brands.


Versatility Without Limits

Choose from a wide selection of sample preparation devices, injection units, and detectors to build a tailored Nexis GC-2060 configuration that meets your application requirements and maximizes analytical efficiency.

Nexis GC-2060

 

Application Highlights

Discover application notes and technical guides that help you set up, validate, and optimize your Nexis GC-2060 workflows.

 

 

 

 

 

 


 

Unlock high-performance, low-effort GC — talk to our team!

 


 

 

Explore more solutions for your analysis

Explore related products to find the right technique and capacity for your samples and regulations.

 

{"title":"Downloads","description":"Download the latest brochure.","source":"product","key":5865,"max":30,"filter_types":["brochures"],"link_title":"View other Downloads","link_url":"","pdf_links":[]} {"title":"Applications","source":"product","key":5865,"max":3,"filter_types":["applications","application_note","posters"],"link_title":"Learn more","link_url":false,"config_list":[],"page_links":[],"column_title":"Documents"} {"title":"Technical Documents","source":"product","key":5865,"max":3,"filter_types":["technical","technical_reports","white_papers","primers"],"link_title":"Learn more","link_url":"#table_anchor_technical","config_list":[],"page_links":[],"column_title":"Documents"} {"title":"Manuals","source":"product","key":5865,"max":3,"filter_types":["manuals"],"link_title":"Learn more","link_url":"#table_anchor_manual","config_list":[],"page_links":[],"column_title":"Documents"}