Shimadzu GC Driver for OpenLab CDS - Specs
Shimadzu GC Driver
Product Lineup
Description | Version | Versions with Functionality Verified |
---|---|---|
Shimadzu GC Driver Single for OpenLab CDS 2 | 2.30 | OpenLab CDS 2.5 / 2.6 / 2.7 |
Shimadzu GC Driver Single for OpenLab EZChrom | 2.30 | OpenLab EZChrom A.04.09, A.04.10 |
• The same product is used both for standalone and network versions of OpenLab systems.
• To install the driver in an existing OpenLab system, please provide the version of applicable software and other relevant information in advance.
Controllable Hardware
GC Unit | Nexis GC-2030, GC-2010 Plus, GC-2010, GC-2010 Pro, GC-2014, GC-2014C |
---|---|
Options | AOC-30i autoinjector, AOC-20i (Plus) autoinjector, AOC-20s (U) autosampler, HS-20 (NX)/HS-10 headspace sampler, dual injection system |
Nexis GC-2030
Sample injector |
SPL-2030, WBI-2030, OCI-2030, PTV-2030, SINJ-2030, OCI-2030NX |
---|---|
Detector |
FID-2030, TCD-2030, ECD-2010 Exceed, FPD-2030, FTD-2030, BID-2030, SCD-2030, PTCD-2030 |
Advanced flow technology |
Backlash, detector splitting, detector switching, heart-cut system |
Additional temperature controller |
Auxiliary temperature control unit |
Additional flow controller |
APC (3 auxiliary channels), APC (1 auxiliary channel) |
Options |
Gas Selector |
• Up to four Shimadzu GC units can be controlled from a single computer or acquisition server (such as an AIC).
• Both the Shimadzu GC driver and Shimadzu LC driver can be installed on the same computer or acquisition server (such as an AIC).
• A Shimadzu GC system and Agilent GC system cannot be connected to the same computer or acquisition server (such as an AIC) at the same time.
Provide a data acquisition server dedicated for the Shimadzu GC system separately.
GC-2010 (Plus/Pro) and GC-2014 (C)
Sample injector |
GC-2010 (Plus/Pro): SPL-2010 (Plus), WBI-2010 (Plus), OCI/PTV-2010 (Plus) |
---|---|
Detector |
GC-2010 (Plus/Pro) : FID-2010 (Plus), TCD-2010 (Plus), ECD-2010 Exceed, ECD-2010 (Plus), FPD-2010 (Plus), FTD-2010 (Plus), BID-2010 Plus |
Additional temperature controller |
Auxiliary temperature control unit |
Additional flow controller |
APC (3 auxiliary channels), AMC (2 auxiliary channels) Note: AMC is an option for the GC-2014 |
Options |
CRG-2010 low-temperature control solenoid valve set |
• Up to four Shimadzu GC units can be controlled from a single computer or acquisition server (AIC etc.).
• Both the Shimadzu GC driver and Shimadzu LC driver can be installed on the same computer or acquisition server (AIC etc.).
• A Shimadzu GC system and an Agilent GC system cannot be connected to the same computer or acquisition server (AIC etc.) at the same time. Please provide a dedicated data acquisition server for the Shimadzu GC system.