Headspace / Purge and Trap Injection

When a gaseous sample is injected, the main function of the liner is to transfer the sample efficiently into the analytical column, as there is no vaporization step needed. Therefore, the suggested liners are thin and straight through, so that the sample band remains as focused as possible when reaching the column. Wool is typically not needed. To avoid backflash, check the expansion volume of your solvent and make sure to choose a liner that has enough volume.

Standard recommendation:

221-41544-05 - for standard HS / P&T applications

 

Specifications & Ordering Information

P/N   Volume [µl] Description
221-75196
221-75196
40 Straight liner with 0.75 mm ID
221-41544-04
221-41544-05
500 Straight liner with 2.6 mm ID
221-75190
221-75190
860 Straight liner with 3.4 mm ID


Each P/N includes 5 deactivated liners. (Standard deactivation: max. temp. 400 °C) 

SPME - Solid Phase Microextraction

nd analyte enrichment. Similar to headspace injections, there is no vaporization step needed in the injector, only the desorption of the analytes from the fiber and their efficient transport into the column is needed. Therefore, SPME liners are straight through liners with no wool and an ID slightly bigger than the OD of the fibers. That way the sample band remains as focused as possible when reaching the column.

Standard recommendation:

221-75196      - for SPME Fibers
227-35327-03 - for 1.1 mm OD Arrows
227-35328-03 - for 1.5 mm OD Arrows

 

Specifications & Ordering Information

P/N   I.D. [mm] Description
221-75196
221-75196
0.75 SPME liner; standard deactivated (5 pcs)
961-01482-07
961-01482-07
0.75

SPME liner for reactive compounds

(e.g. chlorinated pesticides);
Siltek deactivated (5 pcs)
227-35327-03
227-35327-03
1.3 SPME liner for Arrows with 1.1 mm OD;
standard deactivated (3 pcs)
227-35328-03
227-35328-03
1.7 SPME liner for Arrows with 1.5 mm OD;
standard deactivated (3 pcs)


The maximum temperatures depend on the deactivation:

Standard deactivation: 400 °C
Siltek deactivation: 380 °C
These liners should should not be used at higher temperatures than those defined by the SPME fibers/arrows. 

{"title":"Downloads","description":"Download the latest brochure.","source":"product","key":5077,"max":30,"filter_types":["brochures"],"link_title":"View other Downloads","link_url":"","pdf_links":[]} {"title":"Applications","source":"product","key":5077,"max":3,"filter_types":["applications","application_note","posters"],"link_title":"Learn more","link_url":false,"config_list":[],"page_links":[],"column_title":"Documents"} {"title":"Technical Documents","source":"product","key":5077,"max":3,"filter_types":["technical","technical_reports","white_papers","primers"],"link_title":"Learn more","link_url":"#table_anchor_technical","config_list":[],"page_links":[],"column_title":"Documents"} {"title":"Manuals","source":"product","key":5077,"max":3,"filter_types":["manuals"],"link_title":"Learn more","link_url":"#table_anchor_manual","config_list":[],"page_links":[],"column_title":"Documents"}