DPiMS™-8060 Method Package for Rapid Toxicology Screening Ver.2

Simple pretreatment for blood and urine samples in only 2 minutes

With the DPiMS-8060, time-consuming pretreatment steps associated with forensic samples are almost completely eliminated. Begin analysis after only simple dilution and centrifugation steps. The DPiMS-8060 is therefore extremely well-suited for mass analysis via rapid screening.

 

Screening of numerous toxic substances in less than 5 minutes

This method package provides MRM simultaneous analysis methods for approx. 64 compounds (blood samples) or 77 compunds (urine samples) often seen in forensic cases including illicit drugs, narcotics, psychotropics and medical drugs.

 

Ready-to-use method

When using this method package with the DPiMS-8060 for mass analysis, it is no longer necessary to spend time and effort considering analysis conditions or optimizing MS parameters for each compound before starting the analysis. The simultaneous analysis of several compounds can be carried out much more efficiently.

 

Support for easy quantitation from pretreatment to data processing

For each compound in the method package, calibration curve information for internal standards is listed, enabling easy quantitation post-analysis.

 

Easily change units for LC-MS/MS analysis

DPiMS-8060 is an optional ionization kit for the LCMS-8045/8050/8060. It is simple for users to change units to an ESI unit for LC-MS/MS analysis. For example, change between interfaces to quickly check whether a compound has been detected with DPiMS or carry out LC-MS/MS analysis including detailed quantitation.

 

Software that prioritizes simplicity

PESI MS Solution is dedicated software which allows the user to begin analysis by simply selecting the method, setting the sample in place, and pressing the start button. Once analysis is complete, it is easy to create a report file showing the presence or absence of the target compounds.

 

Compounds in the database

For blood samples (shown in red): 64 compounds    For urine samples (shown in blue): 77 compounds
Figures shown in black are for both blood and urine samples.
Abused drugs etc. Narcotics, psychotropics etc. Antipsychotics etc.
Acetyl Fentanyl
Cocaine
Dihydrocodeine
Diphenidine
Ketamine
MDA
MDMA
Methamphetamine
Morphine
Alprazolam
Bromazepam
Brotizolam
Chlordiazepoxide
Clobazam
Clotiazepam
Cloxazolam
Diazepam
Desmethyldiazepam
Diphenhydramine
Estazolam
Etizolam
Fludiazepam
Flunitrazepam
Flurazepam
Haloxazolam
Lormetazepam

Medazepam
Mexazolam
Midazolam
Nimetazepam
Nitrazepam
Oxazepam
Pemoline
Prazepam
Quazepam
Temazepam
Triazolam
Zolpidem
Zopiclone
Amitriptyline
Amoxapine
Blonanserin
Carpipramine
Chlorpromazine
Clocapramine
Clomipramine
Clozapine
Desipramine
Dosulepin
Duloxetine
Escitalopram
Fluvoxamine
Imipramine
Lamotrigine

Levomepromazine
Maprotiline
Mianserin
Milnacipran
Mirtazapine
Nortriptyline
Paroxetine
Perospirone

Perphenazine
Pimozide
Promethazine
Propericiazine
Quetiapine
Risperidone
Sertraline
Sulpiride
Tandospirone
Trazodone
Zotepine
Other compounds Metabolites
Atropine
Bupivacaine
Carbamazepine

Colchicine
Lidocaine
Sildenafill
Tofisopam

Verdenafil
Desmethylclotiazepam
p-hydroxymethamphetamine
7-Aminoflunitrazepam
7-Aminonitrazepam

Cautions

  1. Concentrations calculated with this method package are approximate values, and may differ significantly from true values depending on the samples used and the condition of the equipment. Such values should not form the basis for legal or medical decisions. In order to obtain accurate quantitative values, a quantitative method using calibration curves from standard samples is required.
  2. Shimadzu provides no guarantee with regards to the accuracy of information included in the database or the usefulness of information obtained using the database.
  3. Appropriate quality control tests should be carried out using standard samples to confirm qualitative information obtained with this method package.

DPiMS is a trademark of Shimadzu Corporation.

{"title":"Downloads","description":"Download the latest brochure.","source":"product","key":3172,"max":30,"filter_types":["brochures"],"link_title":"View other Downloads","link_url":"","pdf_links":[]} {"title":"Applications","source":"product","key":3172,"max":3,"filter_types":["applications","application_note","posters"],"link_title":"Learn more","link_url":false,"config_list":[],"page_links":[],"column_title":"Documents"} {"title":"Technical Documents","source":"product","key":3172,"max":3,"filter_types":["technical","technical_reports","white_papers","primers"],"link_title":"Learn more","link_url":"#tbaleAnchor_technical","config_list":[],"page_links":[],"column_title":"Documents"} {"title":"Manuals","source":"product","key":3172,"max":3,"filter_types":["manuals"],"link_title":"Learn more","link_url":"#tbaleAnchor_manual","config_list":[],"page_links":[],"column_title":"Documents"}