MALDI EasyCare - Features

Upgrade for the MALDI-8000 series

Upgrade for the MALDI-8000 series

Upgrade to suit your workflow:

  • MALDI-8020 and dual-polarity MALDI-8030* can be upgraded with MALDI EasyCare functionality using software licence activation from the upgrade kit
    *EasyCare-ready versions only.
  • Upgrading to MALDI EasyCare provides you the control you need over increasing uptime with demanding applications such as MALDI imaging and high-throughput analysis of biological samples
Expanded range in MALDI-8000 series

Manual source cleaning

Easily remove, clean and re-fit ion optics to restore performance.

test Easy access route to ion optics
test Remove / re-fit ion optics with simple twist action
test Clean ion optics

Automated software tuning

  • No technical expertise is required - step-by-step guidance provided by the software wizard.
  • Redirect your laboratory time to value-added activities to improve your productivity - when tuning slide is inserted the software performs the tuning of deflectors and detector for you 
Software wizard provides ‘read-and-click’ guidance and progress information

Software wizard provides ‘read-and-click’ guidance and progress information

  • Automated deflector tuning by software

    Automated deflector tuning by software

  • Automated detector tuning by software

    Automated detector tuning by software

MALDI-8000 series provides class-leading performance

  • MALDI-8020 EasyCare and MALDI-8030 EasyCare retain the same performance as the MALDI-8020 and MALDI-8030
  • The class leading mass resolution and sensitivity provides great value and outstanding data you need for MALDI imaging workflows
MALDI-8000 series provides class-leading performance

Immunohistochemistry MALDI mass spectrometry imaging (IHC-MALDI MSI) of  human tonsil using 20 probes in a single analysis (MALDI image above produced from overlay of probes for CD44 (m/z 1102), CD11b (m/z 1467) and CD20 (m/z 996); full list of probes analysed in experiment listed below)

Experiment details: 30138 profiles acquired at 200 Hz laser speed over duration of 4 hrs 11 mins in positive ion mode at 30 µm spatial resolution on MALDI-8020. Matrix deposition with Shimadzu automated sublimation device iMLayer using DHB MALDI matrix

20-plex markers: CD11b, CD20 , CD3e, CD4, CD44, CD45RO, CD45RA, CD68 , CD8α, ECAD, GZMB, HER2, Histone H3, Ki67, NCAM1 (CD56), PD1, PDGFR-B, PDPN, PR-A/B, PTEN. Probes provided by AmberGen 