HITS-X Series - Specs
High-Speed Impact Testing Machines
High Speed Tensile Testing Machine HITS-TX
Main Unit, Controller and Software
| Product Number | 346-72545 | 
|---|---|
| Impact Test Force | 10 kN | 
| Maximum Speed | 20 m/s | 
| Range Of Speed Settings | 0.0001 m/s to 20 m/s*1 | 
| Piston stroke | 300 mm | 
| Force Amplifier | Range: 20%, 50% or 100% of load detector rating / Accuracy: Within 1.0% of full scale Response frequency: DC- 100 kHz (-3 dB) | 
| Displacement Amplifier | Range: 10%, 20%, 50% or 100% of 150 mm / Accuracy: Within 1.0% of full scale Response frequency: DC- 10 kHz (-3 dB) | 
| AD Converter | Sampling rate: Max. 2 MHz with 12-bit resolution | 
| Acceleration Jig | Tapered acceleration mechanism | 
| Hydraulic Pressure Supply | Model AF-7H, 7 L /min, air cooled, installed below main unit | 
| Safety Devices | Door open/close interlock switch Safety mat interlock switch Two-switch start operation Start timer, etc. | 
| Controller | Model 4870 controller (specialized for high-speed impact testing) | 
| Software | High-speed impact testing software | 
| PC Environment Required for Operation*2 | Compatible OS: Windows 10 (Japanese, English) / Memory capacity: 4 GB or more / | 
| Power Supply Requirements | 200 V 3-phase 6 kVA, 100 V single-phase 1.5 kVA | 
| Air Supply Requirements | Not required | 
| Dimensions (Main Testing Unit) | Approx. W1,100 × D700 × H2,850 mm | 
| Weight (Main Testing Unit) | Approx. 1,500 kg | 
*1: Duration of one test must be within five minutes.
*2: The computer and operating system are not included in the standard system configuration. Please acquire them separately.
High Speed Puncture Impact Testing Machine HITS-PX
Main Unit, Controller and Software
| Product Number | 346-72457 | 
|---|---|
| Impact Test Force | 10 kN | 
| Maximum Speed | 20 m/s | 
| Range Of Speed Settings | 1 m/s to 20 m/s | 
| Piston stroke | 300 mm | 
| Force Amplifier | Range: 20%, 50% or 100% of load detector rating / Accuracy: Within 1.0% of full scale Response frequency: DC- 100 kHz (-3 dB) | 
| Displacement Amplifier | Range: 10%, 20%, 50% or 100% of 150 mm / Accuracy: Within 1.0% of full scale Response frequency: DC- 10 kHz (-3 dB) | 
| AD Converter | Sampling rate: Max. 2 MHz with 12-bit resolution | 
| Specimen Holder | Pneumtic clamping | 
| Hydraulic Pressure Supply | Model AF-7H, 7 L /min, air cooled, installed below main unit | 
| Safety Devices | Door open/close interlock switch Safety mat interlock switch Two-switch start operation Start timer, etc. | 
| Controller | Model 4870 controller (specialized for high-speed impact testing) | 
| Software | High-speed impact testing software | 
| PC Environment Required for Operation*2 | Compatible OS: Windows 10 (Japanese, English) / Memory capacity: 4 GB or more / | 
| Power Supply Requirements | 200 V 3-phase 6 kVA, 100 V single-phase 1.5 kVA | 
| Air Supply Requirements | 0.6 to 0.7 Mpa | 
| Dimensions (Main Testing Unit) | Approx. W1,100 × D900 × H2850 mm | 
| Weight (Main Testing Unit) | Approx. 1,500 kg |