    Hyper Vision HPV-X2 - Specs

    High-Speed Video Camera

    Camera Head

    Lens Mount

    Nikon F-mount1)

    Image Sensor

    FTCMOS2 image sensor

    Recording Speed2) (frame rate) : HP mode

    10 Mfps, 5 Mfps (fixed) (fps = frames per second)

    Recording Speed2) (frame rate) : FP mode

    5 Mfps (fixed)

    Recording Speed2) (frame rate) : Both modes

    Variable recording speed between 60 fps and 2 Mfps (in 1/10 ns steps)

    Continuous Recording Capacity : HP mode

    256 frames max.

    Continuous Recording Capacity : FP mode

    128 frames max.

    Resolution : HP mode

    50,000 pixels (zigzag lattice pixel array)3)

    Resolution : FP mode

    100,000 pixels (400 (horizontal) × 250 (vertical))

    Color/Gradations

    Monochrome, 10 bits4)

    Exposure Time5)

    10 Mfps (fixed at 50 ns), 5 Mfps (fixed at 110 ns)
    Variable in a 10 ns interval starting from 200 ns in a range from 60 fps to 2 Mfps

    External Trigger Input

    Two channels (TRIGIN, STANDBY) TTL level (5 V), capable of either positive or negative polarity

    Recording Mode

    Internal trigger, external trigger, continuous trigger

    Synchronization Function

    Capable of synchronized recording with two cameras connected

    Optional Outputs

    Two channels (exposure start timing, trigger detection timing, or other outputs depending on settings)

    Trigger Point Setting

    Can be set to any frame from the second frame onwards.

    Interface

    One 1000 Base-T/100 Base-TX port

    External Monitor Output

    NTSC/PAL output

    Data Memory Format

    10-bit dedicated format, BMP, AVI, JPEG, TIFF (8-bit and 16-bit formats supported)

    Note 1: Shimadzu does not guarantee that all F-mount lenses can be attached.
    Note 2: The recording speed is a reference value. It is not guaranteed to be an accurate value for the time interval between recording frames.
    Note 3: Stored images will be 400 pixels (horizontal) × 250 pixels (vertical).
    Note 4: 10-bit refers to the data format. It does not indicate a guarantee of data precision.
    Note 5: These exposure times are rough indications and are not guaranteed as exact exposure time ratios for all recording speeds.
    Note 6: The FTCMOS2 image sensor used in this camera is manufactured using high accuracy technology, but defective pixels may exist. Note that this is not a defect or failure of the product.

    Read more
    Show Less

    Power Supply Unit

    Power Rating

    Single phase 120 V/220-230 V, 200 VA, 50/60 Hz

    Required Specifications for the Control PC

    Operating system

    Windows 7/ 8.1 Professional (64-bit)1)

    CPU

    Intel Core i5 or faster

    Memory

    4 GB or more

    HDD

    250 GB or more

    Screen Size

    1,366 × 768 or larger

    Interface

    1000 Base-T/100 Base-TX

    External Recording Device

    DVD-RW

    Other Peripherals

    Mouse and keyboard

    Note 1: Windows is a registered trademark of Microsoft Corporation in the USA and other countries.

    Read more
    Show Less

    Environmental Conditions

    Operating temperature range

    5 to 40 ℃

    Operating Humidity Range

    35 to 75 % RH with no condensation

    Storage Temperature Range

    0 to 50 ℃

    Storage Humidity Range

    20 to 80 % RH with no condensation

    Read more
    Show Less

    Size and Weight

    Camera Head

    W160 × D330 × H260 mm, approx. 6.4 kg

    Power Supply Unit

    W150 × D392 × H185 mm, approx. 5.2 kg

    Length of Interface Cable Between Camera and Control Computer

    Approx. 2 m

    Length of Cable Between Camera and Power Supply Unit

    Approx. 2.8 m