EZ Test - Features
Compact Tabletop Tester
Compact Solutions for Performing Tests

Lightweight and Compact
The compact size fits easily on table tops. An "open table" design provides open access from both sides of the table to ensure a large work space.

Convenient to Use
The height of the device has been lowered significantly. This makes it easier to exchange jigs and samples, and to perform a wide variety of operations.

Adjustable Control Panel
An adjustable manual controller allows the user to set the crosshead positioning and start or stop testing. The position and angle of the control panel can be adjusted to match the user's posture.
High-Precision Testing System

High-precision test force measurements are guaranteed with a load cell of up to 5 kN capacity.
The system uses a high-precision load cell that guarantees accuracy to within ±0.5 % of the indicated value (high-precision type) over a wide range, from 1/500 to 1/1 of the rated capacity. This ensures highly reliable evaluation tests over a wide range of loads.
Compliance | JIS B7721 Class 1 |
---|---|
ISO 7500-1 Class 1 | |
EN 10002-2 Grade 1 | |
ASTM E4 |
Note: Shimadzu recommends inspection at an installation site that meets the requirements specied in these standards.
A Range of Models to Meet a Variety of Needs
With 3 tester models and 12 types of load cells available, the most suitable system can be selected from 32 possible combinations. A high-speed model with a return speed of 3000 mm/min signi cantly shortens test cycle times. In addition, power consumption has been reduced by over 55% compared to previous models.

EZ-SX Short Model | EZ-LX Long-Stroke Model | EZ-LX HS Long-Stroke and High-Speed Model | |
---|---|---|---|
Feature | This is ideal for testing foodstuffs, pharmaceuticals and their packaging, and electrical or electronic parts. With a wide range of testing speeds, it can accommodate all sorts of evaluation testing applications. | With a 5 kN maximum capacity, this is perfect for the tensile testing and bend testing of plastics. The 920 mm stroke capacity also makes it perfect for testing rubber, lm, and other materials with large elongation. | The long stroke improves productivity. The 3000 mm/min return speed signi cantly reduces the wait time between tests, even for tests with large displacements. |
Max. Capacity | 500 N | 5 kN | 2 kN |
Max. Stroke | 380 mm | 740 mm | 740 mm |
Test Speed Range | 0.001 to 1000 mm/min | 0.001 to 1000 mm/min | 0.001 to 2000 mm/min |
Max. Return Speed | 1500 mm/min | 1500 mm/min | 3000 mm/min |