Nexera XS inert - Options
Ultra High Performance Liquid Chromatograph
Automates Development of Analytical Conditions
Method Scouting
The process of considering which analytical conditions to specify for LC separation requires evaluating a huge number of possible combinations of columns, mobile phases, column temperatures, and other factors, which can be taxing on analytical personnel. The Nexera method scouting system offers functionality for automatically switching between multiple mobile phase conditions and columns for analysis. Consequently, it can be used to develop methods more efficiently by automating the process of optimizing mobile phase pH, salt concentration, or other analytical condition settings.
Unique Functionality Reduces Data Analysis Work
i-PeakFinder™
The process of identifying peaks obscured by baseline undulations or noise, identifying shoulder peaks with inadequate separation, and so on, can be very tedious and produce results that vary depending on skill level. Shimadzu's unique i-PeakFinder peak integration algorithm is perfect for accurately detecting peaks in troublesome chromatograms.
Carefully Selected Functionality for Supporting Data Analysis
LabSolutions Insight™ Software for LC/MS Data Analysis
This dedicated LC/MS analysis software features functionality that provides powerful support for multiple-component and multi-sample data analysis, such as functionality for flagging, filtering, and peak comparison.
Mobile Phase pH Monitor: pHM-40
In the case of Ion-exchange chromatography or size-exclusion chromatography used for the analysis of proteins or other biomolecules, the mobile phase pH can strongly affect chromatographic separation. The pH monitor pHM-40 continuously monitors the pH of mobile phases to identify any changes in mobile phase pH in real time.
LC-MS Software
-
LabSolutions Insight Biologics is software for analyzing the characteristics of oligonucleotides using the LCMS-9030 or LCMS-9050 quadrupole time-of-flight type (Q-TOF) mass spectrometer.
LC Columns
-
Shim-pack GISS series maintains the same ultra-high inertness and wider pH range as the Shim-pack GIST series while providing rapid separations with symmetric peaks.
Related information
-
The Nexera series is a family of HPLC systems that marries AI and IoT enhancements to set new industry standards.
-
LabSolutions Insight Biologics is software for analyzing the characteristics of oligonucleotides using the LCMS-9030 or LCMS-9050 quadrupole time-of-flight type (Q-TOF) mass spectrometer.
-
Excellent stability and performance could be achieved under a wide range of LC conditions with Shim-pack Scepter LC columns, which are the next generation organic silica hybrid based columns.
-
Shim-pack Bio IEX Columns are available in Q (quaternary ammonium) and SP (sulfopropyl) chemistries and are based...
-
With different pore sizes, Shim-pack Bio Diol LC columns are effective for analysis of aggregates and fragments of mAb, oligonucleotides and carbohydrates.
-
Even for LC columns that claim to be designed for basic compounds, adequate resolution often can not be obtained due to problems such as leading of highly polar basic compounds, peak shape deterioration of acidic compounds, or long equilibration time required for low ionic strength acidic mobile phase.