Specifications Floor Type
Specifications Floor Type
| Model | AGS-100kNXD | AGS-300kND | |||
| Capacity | 100kN | 300kN | |||
| Loading Method | Direct, high-precision, constant-rate strain control using non-backlash precision ball-screw drive | ||||
| Force Measurement |
Accuracy | High- Precision Type (1/500, ±0.5%) |
Within ±0.5% indicated test force (at 1/500 to 1/1 load cell rating) Conforms to EN 10002-2 Grade 0.5, ISO 7500-1 Class 0.5, BS 1610 Class 0.5, and ASTM E4, JIS B7721 Class 0.5.*1 |
Within ±0.5% indicated test force (at 1/250 to 1/1 load cell rating) Conforms to EN 10002-2 Grade 0.5, ISO 7500-1 Class 0.5, BS 1610 Class 0.5, and ASTM E4, JIS B7721 Class 0.5.*1 |
|
| Standard- Precision Type (1/500, ±1%) |
Within ±1% indicated test force (at 1/500 to 1/1 load cell rating) Conforms to EN 10002-2 Grade 1, ISO 7500-1 Class 1, BS 1610 Class 1, and ASTM E4, JIS B7721 Class 1. *1 |
||||
| Calibration | Automatic test force calibration: select tensile, compression, or tensile and compression | ||||
| Crosshead | Speed Range |
0.001 to 800 mm/min (stepless) | 0.001 to 500 mm/min (stepless) | ||
| Max. Return Speed |
1100mm/min | 550mm/min | |||
| Crosshead Speed Accuracy *2 | ±0.1% | ||||
| Crosshead Speed and Permitted Test Force | To load cell capacity across entire speed range | 0.001~200kN:0.001~500mm/min(entire speed range) 200kN~300kN:0.001~400mm/min | |||
| Crosshead - Table Distance (Tensile stroke) *3 | 1255mm (745mm,MWG) | 1475mm (635mm, MWG) | |||
| Effective Test Width | 600mm | ||||
| Crosshead
Position Detection
|
Measurement Method | Optical encoder | |||
| Display Method | Digital display (display resolution: 0.001 mm) | ||||
| Positional Accuracy | ±0.1% indicated value or ±0.01 mm, whichever is larger | ||||
| Sampling Speed | 40 files (PC link: 20 files, standalone controller: 20 files) | ||||
| Test Method Files | 1000Hz max. *4 | ||||
| Standard Functions |
|
||||
| Accessories | Load cell (with CAL cable), Power cable (5 m), turning rod, cable clamps, instruction manual | ||||
| Dimensions |
|
|
|||
| Weight | 525kg | 675kg | |||
| Model | AGS-100kNX | AGS-300kNX | ||
| Power Requirements | 400V model | 200V model | 400V model | 200V model |
| Three phases AC380-440V 50/60Hz 4.5kVA |
A three phase AC200-230V 50/60Hz 6.5kVA |
Three phases AC380-440V 50/60Hz 5.5kVA |
A three phase AC200-230V 50/60Hz 7.5kVA |
|
| Supply voltage fluctuations within ±10% of the set value. | ||||
| C-class (10 Ω max.) grounding resistance. | D-class (100 Ω max.) grounding resistance. | C-class (10 Ω max.) grounding resistance. | D-class (100 Ω max.) grounding resistance. | |
| Operating Environment | Temperature: 5 °C to 40 °C; Humidity: 20% to 80% (no condensation) Floor vibrations: frequency 10 Hz max., amplitude 5 μm max. | |||