Features
Seamless control of Shimadzu LC
Chromeleon Program Editor screen
Shimadzu LC control parameters are set through the Chromeleon Program Editor embedded in the Chromeleon software. These parameters are stored and handled as standard Chromeleon program files so that the instruments are directly controlled from Chromeleon.
- Creation and modification of instrument programs
- Report output of instrument programs
- Direct control
- Solvent blending
- RF Detector 4Ch support
- Multi column oven (Max 4 ovens)
- System check
- Auto purging
Creation and modification of instrument control programs
For Shimadzu instrument control parameters, instrument program creation and modification are possible. The screen layout for Shimadzu instrument control is the same as that of the standard Chromeleon Program Editor screen, and the created programs are stored as standard Chromeleon program files. A control parameter report can be output by Chromeleon.
Program Editor screen and Instrument parameter report output example
Direct control and instrument status monitoring
Column oven ON/OFF and autosampler purge/rinse can be directly controlled from Chromeleon. Instrument status, including pump pressure and oven temperature, can be monitored. Auto-purging before analysis and system check for instrument consumable parts usage are also possible.
Control panel screen
Connected instrument configuration checking
A connected instrument configuration can be checked on Chromeleon, which displays instrument serial numbers and ROM versions so that instrument management is easier. Values for usage of major consumable parts, such as total volume pumped for the plunger seal, also can be checked.
System Configuration and Consumables screens
Digital data acquisition for enhanced reliability
Status data plotting screen
In addition to seamless system control, the detector signal is digitally transmitted to the data system. This eliminates the necessity to add an A/D converter for analogue data acquisition, making system validation easier and more robust. Furthermore, system status information, such as pump pressures and column oven temperature, may be monitored and recorded along with chromatograms, making your analytical data even more reliable.
Regulatory compliance support
Full system control, including autosampler control, uses Chromeleon Program File, and data processing is integrated with Chromeleon software so that the audit trail functions of Chromeleon software are fully utilized. This gives you full confidence in the compliance of the system to regulations such as GLP/GMP and US FDA 21 CFR Part 11.