Dedicated Columns
Dedicated Columns
SH-RtxTM-1614
- 5% diphenyl / 95% dimethyl polysiloxane
- Optimized for PBDE analysis by EPA Method 1614.
- Short column option resolves BDE-209 three times faster, with less thermal breakdown.
- Unique deactivation gives higher BDE-209 response than competitor columns, for greater analytical sensitivity.
- Exceeds EPA Method 1614 resolution criteria for BDE-49 and BDE-71.
| ID | df | Temp. Range | 15 m | 30 m |
|---|---|---|---|---|
| 0.25 mm | 0.10 µm | -60 to 330/360°C | 227-36265-01 | 227-36265-02 |
SH-RtxTM-OPP2
- Dedicated column for organophosphorus pesticides; best column combination for US EPA Method 8141.
- Low bleed - ideal for GC-FPD, GC-NPD, or GCMS analyses.
| ID | df | Temp. Range | 30 m |
|---|---|---|---|
| 0.32 mm | 0.32 µm | -20 to 310/330°C | 221-75887-30 |
SH-RtxTM-CLP / SH-RtxTM-CLP II
- Dedicated columns for organochlorine pesticides and herbicides.
- Low bleed - ideal for high-sensitivity GC-ECD or GCMS analyses.
- Baseline separations in less than 10 minutes.
- Analyze EPA Method 8081B, 8082A, 8151A, 504.1, 515, 508.1, and 552.2 compounds without time-consuming column changes.
- Similar phases: DB-CLP1 / DB-CLP2
Sh-Rtx-CLP
| ID | df | Temp. Range | 30 m |
|---|---|---|---|
| 0.32 mm | 0.32 µm | -20 to 320/340°C | 227-36266-01 |
| 0.50 µm | -20 to 320/340°C | 221-75879-30 |
SH-Rtx-CLP II
| ID | df | Temp. Range | 30 m |
|---|---|---|---|
| 0.32 mm | 0.25 µm | -20 to 320/340°C | 227-36267-01 |
SH-RtxTM-VMS
- Dedicated columns for analyzing volatile organic pollutants by GCMS including methods TO-15, TMS, and EPA 8260.
- Complete separation of U.S. EPA Method 8260 compounds in less than 10 minutes.
| ID | df | Temp. Range | 20 m | 30 m | 60 m |
|---|---|---|---|---|---|
| 0.18 mm | 1.00 µm | -40 to 240/260°C | 227-36412-01 | - | - |
| 0.25 mm | 1.40 µm | -40 to 240/260°C | - | 227-36268-01 | 227-36268-02 |
| 0.32 mm | 1.80 µm | -40 to 240/260°C | - | 227-36269-01 | 227-36269-02 |
SH-FAMEWAXTM
- Dedicated column for FAMEs, specially tested with a FAME mixture.
- Equivalent to USP G16 phase.
- Similar phases: Select FAME, Omegawax
| ID | df | Temp. Range | 30 m |
|---|---|---|---|
| 0.25 mm | 0.25 µm | 20 to 240/250°C | 227-36324-01 |
| 0.32 mm | 0.25 µm | 20 to 240/250°C | 227-36270-01 |
SH-RtxTM-BAC Plus 1 / SH-RtxTM-BAC Plus 2
- Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences..
- Robust and reproducible column chemistry ensures longer column lifetime and consistent results.
SH-Rtx-BAC Plus 1
| ID | df | Temp. Range | 30 m |
|---|---|---|---|
| 0.32 mm | 1.80 µm | -20 to 240/260°C | 227-36260-01 |
| 0.53 mm | 3.00 µm | -20 to 240/260°C | 227-36261-01 |
SH-Rtx-BAC Plus 2
| ID | df | Temp. Range | 30 m |
|---|---|---|---|
| 0.32 mm | 0.60 µm | -20 to 240/260°C | 227-36263-01 |
| 0.53 mm | 1.00 µm | -20 to 240/260°C | 227-36264-01 |
SH-RtxTM-5 Amine / SH-RtxTM-35 Amine
- Dedicated columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogencontaining heterocyclics.
SH-Rtx-5 Amine (Low-polarity phase: Crossbond 5% diphenyl / 95% dimethyl polysiloxane)
| ID | df | Temp. Range | 15 m | 30 m |
|---|---|---|---|---|
| 0.25 mm | 0.25 µm | -60 to 300/315°C | - | 227-36282-01 |
| 0.50 µm | -60 to 300/315°C | 227-36323-01 | 227-36283-01 | |
| 1.00 µm | -60 to 300/315°C | 227-36323-02 | 227-36284-01 | |
| 0.32 mm | 1.00 µm | -60 to 300/315°C | - | 227-36332-02 |
| 1.50 µm | -60 to 290/305°C | - | 227-36285-01 | |
| 0.53 mm | 1.00 µm | -60 to 290/305°C | - | 227-36286-01 |
| 3.00 µm | -60 to 280/295°C | - | 227-36287-01 |
SH-Rtx-35 Amine (Mid-polarity phase: Crossbond 35% diphenyl / 65% dimethyl polysiloxane)
| ID | df | Temp. Range | 30 m |
|---|---|---|---|
| 0.25 mm | 0.50 µm | 0 to 220°C | 227-36288-01 |
| 1.00 µm | 0 to 220°C | 227-36289-01 | |
| 0.32 mm | 1.00 µm | 0 to 220°C | 227-36290-01 |
| 1.50 µm | 0 to 220°C | 227-36291-01 | |
| 0.53 mm | 1.00 µm | 0 to 220°C | 227-36292-01 |
| 3.00 µm | 0 to 220°C | 227-36293-01 |
SH-StabilwaxTM - DA
- Polar phase: CrossbondTM acid-deactivated CarbowaxTM polyethylene glycol
- Dedicated columns for free (underivatized) acids, some inorganic acids.
- Resistant to oxidative damage.
- Equivalent to USP G25 and G35 phases.
- Similar phases: HP-FFAP, DB-FFAP, VF-DA, CP-Wax 58 CB, CP-FFAP CB, Nukol
| ID | df | Temp. Range | 30 m | 60 m |
|---|---|---|---|---|
| 0.25 mm | 0.10 µm | 40 to 250/260°C | 227-36271-01 | - |
| 0.25 µm | 40 to 250/260°C | 221-75981-30 | 227-36272-01 | |
| 0.50 µm | 40 to 250/260°C | 227-36273-01 | 227-36273-02 | |
| 0.32 mm | 0.10 µm | 40 to 250/260°C | 227-36274-01 | - |
| 0.25 µm | 40 to 250/260°C | 227-36321-02 | 227-36275-01 | |
| 0.50 µm | 40 to 250/260°C | 227-36322-02 | 227-36276-01 | |
| 1.00 mm | 40 to 240/250°C | 227-36277-01 | 227-36277-02 | |
| 0.53 mm | 0.25 µm | 40 to 250/260°C | 227-36278-01 | 227-36278-02 |
| 0.50 µm | 40 to 250/260°C | 227-36279-01 | 227-36279-02 | |
| 1.00 µm | 40 to 240/250°C | 227-36280-01 | 227-36280-02 | |
| 1.50 µm | 40 to 230/240°C | 227-36281-01 | 227-36281-02 |
SH-StabilwaxTM - DB
- Polar phase: CrossbondTM base-deactivated CarbowaxTM polyethylene glycol
- Dedicated columns for underivatized amines and other basic compounds, including alkylamines, diamines, triamines, nitrogencontaining heterocyclics. No need for column priming.
| ID | df | Temp. Range | 30 m | 60 m |
|---|---|---|---|---|
| 0.25 mm | 0.25 µm | 40 to 210/220°C | 227-36294-01 | - |
| 0.50 µm | 40 to 210/220°C | 227-36295-01 | - | |
| 0.32 mm | 0.25 µm | 40 to 210/220°C | 227-36296-01 | 227-36296-02 |
| 0.50 µm | 40 to 210/220°C | 227-36297-01 | - | |
| 1.00 µm | 40 to 210/220°C | 227-36298-01 | - | |
| 0.53 mm | 0.50 µm | 40 to 210/220°C | 227-36299-01 | - |
| 1.00 µm | 40 to 210/220°C | 227-36300-01 | 227-36300-02 |