High-Performance Columns
High-Performance Columns
SH-RxiTM-1MS

- Non-polar phase: CrossbondTM 100% dimethyl polysiloxane
- Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
- General-purpose columns for arson accelerants, essential oils, hydrocarbons, pesticides, PCB congeners (e.g., Aroclor mixes), sulfur compounds, amines, solvent impurities, simulated distillation, oxygenates, gasoline range organics (GRO), refinery gases.
- Equivalent to USP G2 phase.
- Similar phases: HP-1ms UI, HP-1ms, DB-1ms UI, DB-1ms, Ultra-1, VF-1ms, SPB-1, Equity-1
Capillary Columns
High-Performance Columns
SG-Rxi-1MS
| ID | df | Temp. Range | 15 m | 20 m | 25 m | 30 m | 50 m | 60 m |
|---|---|---|---|---|---|---|---|---|
| 0.15 mm | 0.15 µm | -60 to 330/350°C | - | 227-36001-01 | - | - | - | - |
| 2.00 µm | -60 to 330/350°C | - | 227-36002-01 | - | - | - | - | |
| 0.18 mm | 0.18 µm | -60 to 330/350°C | - | 221-75921-20 | - | - | - | - |
| 0.36 µm | -60 to 330/350°C | - | 227-36003-01 | - | - | - | - | |
| 0.20 mm | 0.33 µm | -60 to 330/350°C | - | - | 227-36004-01 | - | 227-36004-02 | - |
| 0.25 mm | 0.25 µm | -60 to 330/350°C | 227-36005-01 | - | - | 221-75923-30 | - | 227-36005-02 |
| 0.50 µm | -60 to 330/350°C | 227-36006-01 | - | - | 227-36006-02 | - | 221-75924-60 | |
| 1.00 µm | -60 to 330/350°C | 227-36007-01 | - | - | 227-36007-02 | - | 227-36007-03 | |
| 0.32 mm | 0.25 µm | -60 to 330/350°C | 227-36008-01 | - | - | 221-75926-30 | - | 227-36008-02 |
| 0.50 µm | -60 to 330/350°C | 227-36009-01 | - | - | 227-36009-02 | - | 227-36009-03 | |
| 1.00 µm | -60 to 330/350°C | - | - | - | 227-36010-01 | - | 221-75928-60 | |
| 4.00 µm | -60 to 330/350°C | - | - | - | 227-36011-01 | - | - | |
| 0.53 mm | 0.50 µm | -60 to 330/350°C | 227-36012-01 | - | - | 227-36012-02 | - | - |
| 1.00 µm | -60 to 330/350°C | 227-36013-01 | - | - | 227-36013-02 | - | - | |
| 1.5 µm | -60 to 330/350°C | 227-36014-01 | - | - | 227-36014-02 | - | 227-36014-03 |
SH-RxiTM-5MS

- Low-polarity phase: CrossbondTM 5% diphenyl / 95% dimethyl polysiloxane
- Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
- General-purpose columns for semi-volatiles, phenols, amines, residual solvents, drugs of abuse, pesticides, PCB congeners (e.g., Aroclor mixes), solvent impurities.
- Equivalent to USP G27 and G36 phases.
- Similar phases: HP-5ms UI, HP-5ms, DB-5, Ultra-2, CP Sil 8 CB, SPB-5, Equity-5
Capillary Columns
High-Performance Columns
SH-Rxi-5MS
| ID | df | Temp. Range | 10 m | 15 m | 20 m | 25 m | 30 m | 50 m | 60 m |
|---|---|---|---|---|---|---|---|---|---|
| 0.10 mm | 0.10 µm | -60 to 330/350°C | 227-36342-01 | - | - | - | - | - | - |
| 0.18 mm | 0.18 µm | -60 to 330/350°C | - | - | 227-36015-01 | - | - | - | - |
| 0.30 µm | -60 to 330/350°C | - | - | 227-36016-01 | - | - | - | - | |
| 0.33 µm | -60 to 330/350°C | - | - | 227-36017-01 | - | - | - | - | |
| 0.20 mm | 0.33 µm | -60 to 330/350°C | - | - | - | 227-36018-01 | - | 227-36018-02 | - |
| 0.25 mm | 0.25 µm | -60 to 330/350°C | - | 221-75940-15 | - | - | 221-75940-30 | - | 227-36019-01 |
| 0.40 µm | -60 to 330/350°C | - | - | - | - | 227-36020-01 | - | - | |
| 0.50 µm | -60 to 330/350°C | - | 227-36021-01 | - | - | 221-75941-30 | - | 221-75942-60 | |
| 1.00 µm | -60 to 330/350°C | - | 227-36022-01 | - | - | 227-36022-02 | - | 227-36022-03 | |
| 0.32 mm | 0.25 µm | -60 to 330/350°C | - | 227-36023-01 | - | - | 221-75943-30 | - | 227-36023-02 |
| 0.50 µm | -60 to 330/350°C | - | 227-36024-01 | - | - | 221-75944-30 | - | 227-36024-02 | |
| 1.00 µm | -60 to 330/350°C | - | 227-36025-01 | - | - | 227-36025-02 | - | 227-36025-03 | |
| 0.53 mm | 0.25 µm | -60 to 330/350°C | - | 227-36026-01 | - | - | 227-36026-02 | - | - |
| 0.50 µm | -60 to 330/350°C | - | 227-36027-01 | - | - | 227-36027-02 | - | - | |
| 1.00 µm | -60 to 330/350°C | - | 227-36028-01 | - | - | 227-36028-02 | - | - | |
| 1.50 µm | -60 to 330/350°C | - | 227-36029-01 | - | - | 227-36029-02 | - | - |
SH-RxiTM-1HT

- Non-polar phase: CrossbondTM 100% dimethyl polysiloxane
- 40% longer lifetime from specially designed fused silica tubing.
- Columns processed for high-temperature applications, such as high molecular weight hydrocarbons.
- Similar phases: DB-1HT, AT-1ht
Capillary Columns
High-Performance Columns
SH-Rxi-1HT
| ID | df | Temp. Range | 15 m | 30 m |
|---|---|---|---|---|
| 0.25 mm | 0.10 µm | -60 to 400°C | 227-36087-01 | 227-36087-02 |
| 0.25 µm | -60 to 400°C | - | 227-36088-01 | |
| 0.32 mm | 0.10 µm | -60 to 400°C | 227-36089-01 | 227-36089-02 |
| 0.25 µm | -60 to 400°C | - | 227-36090-01 |
SH-RxiTM-5HT

- Low-polarity phase: CrossbondTM 5% diphenyl / 95% dimethyl polysiloxane
- 40% longer lifetime from specially designed fused silica tubing.
- Columns processed for high-temperature applications, such as mineral oil.
- Similar phases: DB-5HT, VF-5HT
Capillary Columns
High-Performance Columns
SH-Rxi-5HT
| ID | df | Temp. Range | 15 m | 30 m |
|---|---|---|---|---|
| 0.25 mm | 0.10 µm | -60 to 400°C | 221-75933-15 | 227-36091-01 |
| 0.25 µm | -60 to 400°C | 227-36092-01 | 221-75934-30 | |
| 0.32 mm | 0.10 µm | -60 to 400°C | 227-36093-01 | 227-36093-02 |
| 0.25 µm | -60 to 400°C | - | 227-36094-01 | |
| 0.53 mm | 0.15 µm | -60 to 400°C | - | 227-36095-01 |
SH-RxiTM 5Sil MS

- Low-polarity phase: CrossbondTM silarylene phase 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane
- Engineered to be a low-bleed GCMS column.
- Excellent inertness for active compounds.
- General-purpose columns—ideal for GCMS analysis of semi-volatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities, and hydrocarbons.
- Similar phases: DB-5ms UI, DB-5ms, VF-5ms, SLB-5ms
Capillary Columns
High-Performance Columns
SH-Rxi-5Sil MS
| ID | df | Temp. Range | 15 m | 20 m | 30 m | 40 m | 60 m |
|---|---|---|---|---|---|---|---|
| 0.15 mm | 0.15 µm | -60 to 320/350°C | - | 227-36030-01 | - | - | - |
| 2.00 µm | -60 to 320/350°C | - | 227-36031-01 | - | - | - | |
| 0.18 mm | 0.10 µm | -60 to 320/350°C | - | - | - | - | 227-36032-01 |
| 0.18 µm | -60 to 320/350°C | - | 227-36033-01 | - | 227-36033-02 | - | |
| 0.36 µm | -60 to 320/350°C | - | 227-36034-01 | - | - | - | |
| 0.25 mm | 0.10 µm | -60 to 320/350°C | 227-36035-01 | - | 227-36035-02 | - | - |
| 0.25 µm | -60 to 320/350°C | 227-36036-01 | - | 221-75954-30 | - | 227-36036-02 | |
| 0.50 µm | -60 to 320/350°C | 227-36037-01 | - | 227-36037-02 | - | - | |
| 1.00 µm | -60 to 320/350°C | 227-36038-01 | - | 221-75956-30 | - | 227-36038-02 | |
| 0.32 mm | 0.25 µm | -60 to 330/350°C | 227-36039-01 | - | 227-36039-02 | - | - |
| 0.50 µm | -60 to 320/350°C | - | - | 227-36040-01 | - | - | |
| 1.00 µm | -60 to 320/350°C | - | - | 227-36041-01 | - | - | |
| 0.53 mm | 1.50 µm | -60 to 320/350°C | - | - | 227-36032-02 | - | - |
SH-RxiTM XLB
- Low-polarity proprietary phase
- General-purpose columns exhibiting extremely low bleed. Ideal for many GCMS applications, including pesticides, PCB congeners (e.g., Aroclor mixes), PAHs.
- Unique selectivity.
- Similar phases: DB-XLB, VF-Xms
Capillary Columns
High-Performance Columns
SH-Rxi-XLB
| ID | df | Temp. Range | 30 m | 60 m |
|---|---|---|---|---|
| 0.25 mm | 0.10 µm | 30 to 340/360°C | 227-36042-01 | - |
| 0.25 µm | 30 to 340/360°C | 227-36043-01 | 227-36043-02 | |
| 0.50 µm | 30 to 340/360°C | 227-36044-01 | - | |
| 1.00 µm | 30 to 340/360°C | 227-36045-01 | - | |
| 0.32 mm | 0.25 µm | 30 to 340/360°C | 227-36046-01 | 227-36046-02 |
| 0.50 µm | 30 to 340/360°C | 227-36047-01 | - | |
| 1.00 µm | 30 to 340/360°C | 227-36048-01 | - | |
| 0.53 mm | 0.50 µm | 30 to 340/360°C | 227-36049-01 | - |
| 1.50 µm | 30 to 340/360°C | 227-36050-01 | - |
SH-RxiTM 17

- Mid-polarity phase: CrossbondTM 50% diphenyl / 50% dimethyl polysiloxane
- General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, sterols.
- Similar phases: HP-17, DB-17, DB-17HT, DB-608, SPB-17
Capillary Columns
High-Performance Columns
SH-Rxi-17
| ID | df | Temp. Range | 20 m | 30 m |
|---|---|---|---|---|
| 0.18 mm | 0.18 µm | 40 to 280/320°C | 227-36061-01 | - |
| 0.25 mm | 0.25 µm | 40 to 280/320°C | - | 221-75907-30 |
| 0.50 µm | 40 to 280/320°C | - | 227-36062-01 | |
| 1.00 µm | 40 to 280/320°C | - | 227-36063-01 | |
| 0.32 mm | 0.25 µm | 40 to 280/320°C | - | 227-36064-01 |
| 0.50 µm | 40 to 280/320°C | - | 227-36065-01 | |
| 1.00 µm | 40 to 280/320°C | - | 227-36066-01 | |
| 0.53 mm | 0.25 µm | 40 to 280/320°C | - | 227-36067-01 |
| 0.50 µm | 40 to 280/320°C | - | 227-36068-01 | |
| 0.83 µm | 40 to 280/320°C | - | 227-36069-01 | |
| 1.00 µm | 40 to 280/320°C | - | 221-76193-30 | |
| 1.50 µm | 40 to 280/320°C | - | 227-36070-01 |
SH-RxiTM 35Sil MS

- Mid-polarity: CrossbondTM phase (similar to 35% phenyl methyl polysiloxane)
- Very low-bleed phase for GCMS analysis.
- Special selectivity and excellent inertness for substituted polar compounds, such as drugs, pesticides, herbicides, PCBs, phenols, etc.
- Provides superior separation for cannabinoids.
- Similar phases: DB-35ms, DB-35ms UI, VF-35ms
Capillary Columns
High-Performance Columns
SH-Rxi-35Sil MS
| ID | df | Temp. Range | 15 m | 30 m |
|---|---|---|---|---|
| 0.25 mm | 0.25 µm | 50 to 340/360°C | 227-36051-01 | 227-36051-02 |
| 0.50 µm | 50 to 340/360°C | 227-36052-01 | 227-36052-02 | |
| 1.00 µm | 50 to 320/340°C | 227-36053-01 | 227-36053-02 | |
| 0.32 mm | 0.25 µm | 50 to 340/360°C | 227-36054-01 | 227-36054-02 |
| 0.50 µm | 50 to 340/360°C | 227-36055-01 | 227-36055-02 | |
| 1.00 µm | 50 to 320/340°C | 227-36056-01 | 227-36056-02 | |
| 0.53 mm | 0.50 µm | 50 to 340/360°C | 227-36057-01 | 227-36057-02 |
| 1.00 µm | 50 to 320/340°C | 227-36058-01 | 227-36058-02 | |
| 1.50 µm | 50 to 310/330°C | 227-36059-01 | 227-36059-02 | |
| 3.00 µm | 50 to 280/300°C | 227-36060-01 | 227-36060-02 |
SH-RxiTM 17Sil MS

- Mid-polarity CrossbondTM phase (similar to 50% phenyl methyl polysiloxane)
- Low bleed for use with sensitive detectors, such as MS.
- Excellent inertness and selectivity for active environmental compounds, such as PAHs.
- Equivalent to USP G3 phase.
- Similar phases: DB-17ms, HP-17, DB-17, VF-17ms, CP-Sil 24 CB
Capillary Columns
High-Performance Columns
SH-Rxi-17Sil MS
| ID | df | Temp. Range | 30 m | 60 m |
|---|---|---|---|---|
| 0.25 mm | 0.25 µm | 40 to 340/360°C | 221-75916-30 | 227-36071-01 |
| 0.32 mm | 0.25 µm | 40 to 340/360°C | 227-36072-01 | - |
SH-RxiTM PAH
- Mid-polarity proprietary phase
- Ideal for EFSA PAH4 analysis—separates all priority compounds: benz[a]anthracene, chrysene, benzo[b]fluoranthene and benzo[a]pyrene.
- Best resolution of chrysene from interfering PAHs, triphenylene, and cyclopenta[cd]pyrene.
- Equivalent to USP G3 phase.
- Complete separation of benzo [b], [k], [j], and [a] fluoranthenes.
Capillary Columns
High-Performance Columns
SH-Rxi-PAH
| ID | df | Temp. Range | 30 m | 40 m | 60 m |
|---|---|---|---|---|---|
| 0.18 mm | 0.07 µm | to 360°C | - | 227-36073-01 | - |
| 0.25 mm | 0.10 µm | to 360°C | 227-36074-01 | - | 227-36074-02 |
SH-RxiTM 624Sil MS

- Mid-polarity CrossbondTM silarylene phase (similar to 6% cyanopropylphenyl / 94% dimethyl polysiloxane)
- Low-bleed, high-thermal stability column—maximum temperatures up to 300–320 °C.
- Inert—excellent peak shape for a wide range of compounds.
- Selective—G43 phase highly selective for volatile organics and residual solvents, great choice for USP<467>.
- Manufactured for column-to-column reproducibility—well-suited for validated methods.
- Similar phases: HP-624, DB-624, VF-624ms, CP-Select 624 CB
Capillary Columns
High-Performance Columns
SH-Rxi-624Sil MS
| ID | df | Temp. Range | 20 m | 30 m | 60 m | 75 m | 105 m |
|---|---|---|---|---|---|---|---|
| 0.18 mm | 1.00 µm | -20 to 300/320°C | 227-36075-01 | - | - | - | - |
| 0.25 mm | 1.40 µm | -20 to 300/320°C | - | 221-75962-30 | 227-36076-01 | - | - |
| 0.32 mm | 1.80 µm | -20 to 300/320°C | - | 227-36077-01 | 221-75963-60 | - | - |
| 0.53 mm | 3.00 µm | -20 to 280/300°C | - | 227-36078-01 | 227-36078-02 | 227-36078-03 | 227-36078-04 |
SH-RxiTM 1301Sil MS

- Mid-polarity CrossbondTM silarylene phase (similar to 6% cyanopropylphenyl / 94% dimethyl polysiloxane)
- Highest thermal stability in the industry ensures dependable, accurate MS results and increased uptime.
- Stabilized cyano phase selectivity improves the performance of existing methods. Ideal for solvents, glycols, and other polar compounds.
- Rigorous QC testing ensures inertness and accurate, reliable data for multiple compound classes.
- Similar phase: VF-1301ms
Capillary Columns
High-Performance Columns
SH-Rxi-1301Sil MS
| ID | df | Temp. Range | 15 m | 30 m | 60 m |
|---|---|---|---|---|---|
| 0.25 mm | 0.25 µm | -60 to 320°C | - | 227-36079-01 | 227-36079-02 |
| 1.00 µm | -60 to 320°C | - | 227-36080-01 | 227-36080-02 | |
| 0.32 mm | 0.25 µm | -60 to 320°C | - | 227-36081-01 | - |
| 1.00 µm | -60 to 320°C | - | 227-36082-01 | 227-36082-02 | |
| 1.50 µm | -60 to 320°C | - | 227-36083-01 | 227-36083-02 | |
| 0.53 mm | 1.00 µm | -60 to 320°C | 227-36084-01 | 227-36084-02 | - |
| 1.50 µm | -60 to 320°C | - | 227-36085-01 | - | |
| 3.00 µm | -60 to 320°C | - | 227-36086-01 | 227-36086-02 |